All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

CONTINUOUS RADON-IN-WATER MONITORING-COMPARISON OF METHODS UNDER LABORATORY CONDITIONS AND RESULTS OF IN SITU MEASUREMENTS

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F19%3A00356493" target="_blank" >RIV/68407700:21340/19:00356493 - isvavai.cz</a>

  • Alternative codes found

    RIV/86652052:_____/19:N0000031

  • Result on the web

    <a href="https://doi.org/10.1093/rpd/ncz241" target="_blank" >https://doi.org/10.1093/rpd/ncz241</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncz241" target="_blank" >10.1093/rpd/ncz241</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    CONTINUOUS RADON-IN-WATER MONITORING-COMPARISON OF METHODS UNDER LABORATORY CONDITIONS AND RESULTS OF IN SITU MEASUREMENTS

  • Original language description

    The extraction of dissolved radon from water to gas is the most common way to measure radon concentration in water continuously. The response delay of continuous radon-in-water detection system (continuous monitor+ equilibrator) is influenced by the response time of the continuous monitor and a rate of an establishment of equilibrium in the equilibrator (exchanger unit). Two types of equilibrators were used in performed experiments to compare the response time of various detection systems-RAD AQUA that uses water spraying and equilibrator with ACCUREL (R) PP membrane that enables radon diffusion. Each of these was connected to the continuous monitor RAD7 or RM-3. The response delay after turning on the water flow through the equilibrator was determined. The fastest detection system was RAD7 + RAD AQUA that was subsequently tested during the insitu measurement of thermal water in the healing spa and water sources near Cheb and Ceske Budejovice.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

    1742-3406

  • Volume of the periodical

    186

  • Issue of the periodical within the volume

    2-3

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    406-412

  • UT code for WoS article

    000530582200053

  • EID of the result in the Scopus database

    2-s2.0-85082779957