Continuous radon-in-water monitoring – comparison of methods under laboratory conditions and results of in situ measurements

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000031" target="_blank" >RIV/86652052:_____/19:N0000031 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21340/19:00356493

  • Result on the web

    <a href="https://academic.oup.com/rpd/article/186/2-3/406/5674027" target="_blank" >https://academic.oup.com/rpd/article/186/2-3/406/5674027</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncz241" target="_blank" >10.1093/rpd/ncz241</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Continuous radon-in-water monitoring – comparison of methods under laboratory conditions and results of in situ measurements

  • Original language description

    The extraction of dissolved radon from water to gas in the most common way to measure radon concentration in water continuously. The response delay of continuous radon-in-water detection system (continuous monitor + equilibrator) is influenced by the response time of the continuous monitor and a rate of an establishment of equilibrium in the equilibrator (exchanger unit). Two types of equilibrators were used in performed experiments to compare the response time of various detection systems - RAD AQUA that uses water spraying and equilibrator with ACCUREL® PP membrane that enables radon diffusion. Each of these was connected to the continuous monitor RAD7 or RM-3. The response delay after turning on the water flow through the equilibrator was determined. The fastest detection system was RAD7 + RAD AQUA that was subsequently tested during the in-situ measurement of thermal water in the healing spa and water sources near Cheb and České Budějovice.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10511 - Environmental sciences (social aspects to be 5.7)

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

    1742-3406

  • Volume of the periodical

    186

  • Issue of the periodical within the volume

    2-3

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    406–412

  • UT code for WoS article

    000530582200053