Pressure Cost of Volume Delivery In HFOV at Different Ventilatory Frequencies

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F13%3A00210166" target="_blank" >RIV/68407700:21460/13:00210166 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.degruyter.com/view/j/bmte.2013.58.issue-s1-N/bmt-2013-4365/bmt-2013-4365.xml?rskey=geRT6Y&result=2" target="_blank" >http://www.degruyter.com/view/j/bmte.2013.58.issue-s1-N/bmt-2013-4365/bmt-2013-4365.xml?rskey=geRT6Y&result=2</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1515/bmt-2013-4365" target="_blank" >10.1515/bmt-2013-4365</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Pressure Cost of Volume Delivery In HFOV at Different Ventilatory Frequencies

  • Original language description

    Ventilatory pressures and tidal volume were measured during high frequency oscillatory ventilation in the ventilatory circuit. The circuit consisted of ventilator 3100 with patient circuit, lung simulator 5600i and monitor Florian for measuring of tidalvolume. A special device for synchronous measurement of pressure at three places was used for analysis of pressure waves in the ventilatory circuit. Pressure amplitudes and tidal volume was measured for different values of alveolar compliance that was set on the model. Measurement was repeated for ventilatory frequencies 3, 5, 7 and 10 Hz. Ventilatory parameters were held constant during the experiment. We have found that change of alveolar compliance has minimal effect on the pressure cost of ventilation.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Biomedizinische Technik / Biomedical Engineering

  • ISSN

    0013-5585

  • e-ISSN

  • Volume of the periodical

    58

  • Issue of the periodical within the volume

    S1

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    2

  • Pages from-to

  • UT code for WoS article

    000329463600427