All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Compact four-layer Timepix-based particle tracker WidePIX 3D: the first applications in X-ray CT imaging

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F18%3A00329957" target="_blank" >RIV/68407700:21460/18:00329957 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21670/18:00329957

  • Result on the web

    <a href="https://iopscience.iop.org/article/10.1088/1748-0221/13/12/C12001/meta" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/13/12/C12001/meta</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/13/12/C12001" target="_blank" >10.1088/1748-0221/13/12/C12001</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Compact four-layer Timepix-based particle tracker WidePIX 3D: the first applications in X-ray CT imaging

  • Original language description

    WidePIX 3D is a compact Timepix-based particle tracking detector with 3D position sensitivity. The device consists of four Timepix chips with 300 μm silicon sensors tightly stacked together. The sensor volume is, therefore, divided into a 3D array of 256 x 256 x 4 voxels. Dual-energy X-ray imaging with sandwich detector is already known as single-shot dual-energy X-ray radiography utilizing a two-layer detector. In the case of WidePIX 3D, the detector can provide up to four sample images produced by different photon spectra from a single exposure. Furthermore, the detection threshold of each layer can be individually adjusted to optimize the resolving performance for elements expected within the scanned sample. In this contribution we present the first results of using the WidePIX 3D detector as an imaging camera for multi-channel energy-sensitive X-ray CT. The procedure of precise threshold-energy calibration of the detector using characteristic X-ray lines will be described and material-resolving CT data will be demonstrated.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    21100 - Other engineering and technologies

Result continuities

  • Project

    <a href="/en/project/EF16_019%2F0000766" target="_blank" >EF16_019/0000766: Engineering applications of microworld physics</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

    1748-0221

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    C12001

  • Country of publishing house

    IT - ITALY

  • Number of pages

    8

  • Pages from-to

  • UT code for WoS article

    000452067300001

  • EID of the result in the Scopus database