Imaging performance of a Timepix detector based on semi-insulating GaAs

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F18%3A00319854" target="_blank" >RIV/68407700:21670/18:00319854 - isvavai.cz</a>

  • Result on the web

    <a href="http://iopscience.iop.org/article/10.1088/1748-0221/13/01/C01034/" target="_blank" >http://iopscience.iop.org/article/10.1088/1748-0221/13/01/C01034/</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/13/01/C01034" target="_blank" >10.1088/1748-0221/13/01/C01034</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Imaging performance of a Timepix detector based on semi-insulating GaAs

  • Original language description

    This work focused on a Timepix chip [1] coupled with a bulk semi-insulating GaAs sensor. The sensor consisted of a matrix of 256 x 256 pixels with a pitch of 55 mu m bump-bonded to a Timepix ASIC. The sensor was processed on a 350 mu m-thick SI GaAs wafer. We carried out detector adjustment to optimize its performance. This included threshold equalization with setting up parameters of the Timepix chip, such as Ikrum, Pream, Vfbk, and so on. The energy calibration of the GaAs Timepix detector was realized using a Am-241 radioisotope in two Timepix detector modes: time-over-threshold and threshold scan. An energy resolution of 4.4 keV in FWHM (Full Width at Half Maximum) was observed for 59.5 keV gamma-photons using threshold scan mode. The X-ray imaging quality of the GaAs Timepix detector was tested using various samples irradiated by an X-ray source with a focal spot size smaller than 8 gamma m and accelerating voltage up to 80 kV. A 700 gamma m x 700 mu m gold testing object (X-500-200-16Au with Siemens star) fabricated with high precision was used for the spatial resolution testing at different values of X-ray image magnification (up to 45). The measured spatial resolution of our X-ray imaging system was about 4 mu m.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10300 - Physical sciences

Result continuities

  • Project

    <a href="/en/project/EF16_013%2F0001785" target="_blank" >EF16_013/0001785: Van de Graaff Accelerator - a Tunable Source of Monoenergetic Neutrons and Light Ions</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

    1748-0221

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    January

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    10

  • Pages from-to

  • UT code for WoS article

    000423302400009

  • EID of the result in the Scopus database

    2-s2.0-85041830406