All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Educational Pulse Oximeter Controlled by Microprocessor

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F22%3A00362444" target="_blank" >RIV/68407700:21460/22:00362444 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1109/EHB55594.2022.9991740" target="_blank" >https://doi.org/10.1109/EHB55594.2022.9991740</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EHB55594.2022.9991740" target="_blank" >10.1109/EHB55594.2022.9991740</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Educational Pulse Oximeter Controlled by Microprocessor

  • Original language description

    One of the foremost vital signs observed is monitoring patients' oxygenation using pulse oximeters. Therefore, understanding this continuously improving pulse oximetry technology and its relation to the education of Biomedical engineers is essential. The aim of this project is to design a pulse oximeter that will allow students to view and analyze the plethysmographic curve, obtain the peripheral blood oxygen saturation (SpO2) value in percentage and obtain the heart rate (HR) value in beats per minute (bpm). The hardware consists of a commercially available SpO2 sensor, Arduino microprocessor and a data preprocessing circuit. The software part is implemented in Simulink. The flashing of the LEDs is controlled by software with a frequency of 200 Hz. Arduino microprocessor reads the signals for red and infrared radiation. Subsequently, two plethysmographic curves are software filtered, and SpO2 and HR values are determined. The implemented pulse oximeter PulseOx was tested on a SpO2 simulator - perfusion index (PI) set at 20%, and the HR set at 60 bpm, SpO2 values ranging from 60% to 100% were measured with a mean difference between the SpO2 simulator and PulseOx of -0.23% and a standard deviation difference of 2.73 %. For HR values from 40 bpm to 180 bpm, values with a mean difference of 2.26 bpm were recorded.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20601 - Medical engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of 2022 E-Health and Bioengineering Conference (EHB)

  • ISBN

    978-1-6654-8557-9

  • ISSN

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

  • Publisher name

    Gr. T. Popa University of Medicine and Pharmacy

  • Place of publication

    Iasi

  • Event location

    Iasi

  • Event date

    Nov 17, 2022

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article