Assessment of the Diagnostic Efficacy of Low-Field Magnetic Resonance Imaging: A Systematic Review
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F24%3A00376574" target="_blank" >RIV/68407700:21460/24:00376574 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.3390/diagnostics14141564" target="_blank" >https://doi.org/10.3390/diagnostics14141564</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/diagnostics14141564" target="_blank" >10.3390/diagnostics14141564</a>
Alternative languages
Result language
angličtina
Original language name
Assessment of the Diagnostic Efficacy of Low-Field Magnetic Resonance Imaging: A Systematic Review
Original language description
Background: In recent years, there has been an increasing effort to take advantage of the potential use of low magnetic induction devices with less than 1 T, referred to as Low-Field MRI (LF MRI). LF MRI systems were used, especially in the early days of magnetic resonance technology. Over time, magnetic induction values of 1.5 and 3 T have become the standard for clinical devices, mainly because LF MRI systems were suffering from significantly lower quality of the images, e.g., signal-noise ratio. In recent years, due to advances in image processing with artificial intelligence, there has been an increasing effort to take advantage of the potential use of LF MRI with induction of less than 1 T. This overview article focuses on the analysis of the evidence concerning the diagnostic efficacy of modern LF MRI systems and the clinical comparison of LF MRI with 1.5 T systems in imaging the nervous system, musculoskeletal system, and organs of the chest, abdomen, and pelvis. Methodology: A systematic literature review of MEDLINE, PubMed, Scopus, Web of Science, and CENTRAL databases for the period 2018-2023 was performed according to the recommended PRISMA protocol. Data were analysed to identify studies comparing the accuracy, reliability and diagnostic performance of LF MRI technology compared to available 1.5 T MRI. RESULTS: A total of 1275 publications were retrieved from the selected databases. Only two articles meeting all predefined inclusion criteria were selected for detailed assessment. Conclusions: A limited number of robust studies on the accuracy and diagnostic performance of LF MRI compared with 1.5 T MRI was available. The current evidence is not sufficient to draw any definitive insights. More scientific research is needed to make informed conclusions regarding the effectiveness of LF MRI technology.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20601 - Medical engineering
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Diagnostics
ISSN
2075-4418
e-ISSN
2075-4418
Volume of the periodical
14
Issue of the periodical within the volume
14
Country of publishing house
CH - SWITZERLAND
Number of pages
15
Pages from-to
—
UT code for WoS article
001276708200001
EID of the result in the Scopus database
2-s2.0-85199616507