All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Development of a versatile deep hyperthermia treatment planning tool

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F25%3A00384221" target="_blank" >RIV/68407700:21460/25:00384221 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1016/j.ejmp.2025.105035" target="_blank" >https://doi.org/10.1016/j.ejmp.2025.105035</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.ejmp.2025.105035" target="_blank" >10.1016/j.ejmp.2025.105035</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Development of a versatile deep hyperthermia treatment planning tool

  • Original language description

    Purpose: To develop and test a versatile deep hyperthermia treatment planning (HTP) tool. Methods: A patient automatic positioning routine following manual clinical procedure was implemented into a newly developed versatile HTP tool. For 70 patients treated using Sigma 60 applicator, 48 patients with the Sigma Eye applicator, we compared predicted specific absorption rate (SAR) indicators obtained by manual and automatic positioning routines. We used the target to hotspot coefficient (THQ) representing the ratio between average SAR in target and hotspot, TC25 and TC50 defined as target volume enclosed with 25% and 50% SAR iso-contour. Further, we created example HTP setups for Sigma Ellipse, Alba4D and AMC8 applicators demonstrating the versatility of the tool. Results: For the Sigma 60 and the Sigma Eye, we found a highest average relative difference of 2% for all studied SAR indicators when comparing manual and automatically created HTP setups. Overall, the automatic positioning procedure is highly efficient and operator time for building a single patient specific HTP setup is 10-20 min faster. Conclusion: On average, the automatic positioning routine is more time efficient and provides similar SAR target coverage compared to manual positioning by experienced staff. The reduced time requirement supports wider HTP acceptance in the clinical routine.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20601 - Medical engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS

  • ISSN

    1120-1797

  • e-ISSN

    1724-191X

  • Volume of the periodical

    136

  • Issue of the periodical within the volume

    105035

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    9

  • Pages from-to

  • UT code for WoS article

    001523209500001

  • EID of the result in the Scopus database

    2-s2.0-105009003332