Calibration of the Combination Factor for Fire Design Situation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21610%2F02%3A07080456" target="_blank" >RIV/68407700:21610/02:07080456 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Calibration of the Combination Factor for Fire Design Situation
Original language description
The reliability based study on the combination factor Psi for variable action Q is based on the design procedure recommended in EN 1990 Basis of Structural Design and in EN 1991-1-2 Actions on Structures - Part 2/2: Actions on Structures Exposed to Fire.Submitted investigation of a steel component is primarily focused on application of expression (6.11) of EN 1990. It appears that the combination factor Psi should be specified taking into account the type and extent of compartment area A, active and passive measures, and the load ratio Chi = Qk/(Gk+Qk)of the characteristic values of a variable load Qk and the total load Gk+Qk. It is further shown that in particular structural conditions the combination factor Psi may be optimised to achieve the minimum total cost.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JN - Civil engineering
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2002
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Eurosteel 2002
ISBN
972-98376-3-5
ISSN
—
e-ISSN
—
Number of pages
6
Pages from-to
1421-1426
Publisher name
Universidade de Coimbra
Place of publication
Coimbra
Event location
Coimbra
Event date
Sep 19, 2002
Type of event by nationality
WRD - Celosvětová akce