Measurement of Decay of Radioactive and Isomer Nuclei by Spatial and Time Coincidence in the Timepix Pixel Detector

Result description

The high granularity of the pixel detector allows applying not only temporal but also spatial coincidence technique for background suppression. This is particularly important for scarcely populated nuclei and/or detection under high rate of unwanted/background events. For these different situations two methods were developed using a segmented ionization chamber as trigger: (i) a time-delayed opening (start) of the detector shutter, and (ii) a trigger-driven external clock with varying time delay with the detector shutter open. For these approaches, Timepix was operated in its time mode and in its time-over-threshold mode, respectively. The methods are demonstrated on the detection and decay measurement of 8He and 6He ions as well as of the 7.6 ?s 496.2keV isomer 98mY, respectively.

Keywords

Radioactive nucleiradiation detectionPixel detector

The result's identifiers

Alternative languages

  • Result language

    angličtina

  • Original language name

    Measurement of Decay of Radioactive and Isomer Nuclei by Spatial and Time Coincidence in the Timepix Pixel Detector

  • Original language description

    The high granularity of the pixel detector allows applying not only temporal but also spatial coincidence technique for background suppression. This is particularly important for scarcely populated nuclei and/or detection under high rate of unwanted/background events. For these different situations two methods were developed using a segmented ionization chamber as trigger: (i) a time-delayed opening (start) of the detector shutter, and (ii) a trigger-driven external clock with varying time delay with the detector shutter open. For these approaches, Timepix was operated in its time mode and in its time-over-threshold mode, respectively. The methods are demonstrated on the detection and decay measurement of 8He and 6He ions as well as of the 7.6 ?s 496.2keV isomer 98mY, respectively.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    BG - Nuclear, atomic and molecular physics, accelerators

  • OECD FORD branch

Result continuities

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    XXXIII Workshop Nuclear Physics in Brazil

  • ISBN

    978-0-7354-0908-8

  • ISSN

    0094-243X

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    99-103

  • Publisher name

    American Institute of Physics

  • Place of publication

    New York

  • Event location

    Brazil

  • Event date

    Sep 7, 2010

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article