Simulation of a silicon neutron detector coated with TiB2 absorber
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F12%3A00191447" target="_blank" >RIV/68407700:21670/12:00191447 - isvavai.cz</a>
Result on the web
<a href="http://iopscience.iop.org/1748-0221/7/01/C01096" target="_blank" >http://iopscience.iop.org/1748-0221/7/01/C01096</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/7/01/C01096" target="_blank" >10.1088/1748-0221/7/01/C01096</a>
Alternative languages
Result language
angličtina
Original language name
Simulation of a silicon neutron detector coated with TiB2 absorber
Original language description
Neutron radiation cannot be directly detected in semiconductor detectors and therefore needs converter layers. Planar clean-room processing can be used in the manufacturing process of semiconductor detectors with metal layers to produce a cost-effectivedevice. We used the Geant4 Monte-Carlo toolkit to simulate the performance of a semiconductor neutron detector. A silicon photo-diode was coated with vapour deposited titanium, aluminium thin films and a titaniumdiboride (TiB2) neutron absorber layer. The neutron capture reaction 10B(n, alpha)7Li is taken advantage of to create charged particles that can be counted. Boron-10 has a natural abundance of about SI 19.8%. The emitted alpha particles are absorbed in the underlying silicon detector. We variedthe thickness of the converter layer and ran the simulation with a thermal neutron source in order to find the best efficiency of the TiB2 converter layer and optimize the clean room process.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BF - Elementary particle theory and high energy physics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/LA08015" target="_blank" >LA08015: Collaboration of the Czech Republic with CERN</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Volume of the periodical
2012
Issue of the periodical within the volume
7
Country of publishing house
IT - ITALY
Number of pages
7
Pages from-to
1-7