All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Improved Fast Neutron Detector Based on Timepix and Plastic Scintillating Converter

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F17%3A00338434" target="_blank" >RIV/68407700:21670/17:00338434 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1109/NSSMIC.2016.8069789" target="_blank" >https://doi.org/10.1109/NSSMIC.2016.8069789</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/NSSMIC.2016.8069789" target="_blank" >10.1109/NSSMIC.2016.8069789</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Improved Fast Neutron Detector Based on Timepix and Plastic Scintillating Converter

  • Original language description

    The detection of fast neutrons by recoiled protons from a plastic scintillator situated very close to the pixel detector Timepix was introduced. The directional sensitivity of the detection was proven when signal generated by the scintillating light collected by silicon photomultipliers (SiPM) was used for triggering and synchronization of the system. In the proposed contribution the technique refines measuring the analog value of the scintillation light from all segments of an array 4x4 of silicon photomultipliers. Position and energy sensitivity of the silicon pixel detector Timepix is supplemented by position and energy sensitivity of the plastic scintillator. Each of 16 SiPM segments is connected to the independent channel of the spectroscopic ASIC VATA64HDR16. The ASIC provides trigger signal for the system including the pixel detector readout interface FITPix. Variable threshold allows changing the sensitive level and omitting SiPM dark noise or low-energetic particles. Sampled and hold analog value can be readout channel-by-channel through an analog multiplex and converted by an ADC for further digital processing. The whole activity is controlled by a FPGA. The results of measurements with a laboratory radioactive source (AmBe) will be presented.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    21100 - Other engineering and technologies

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016

  • ISBN

    978-1-5090-1642-6

  • ISSN

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

  • Publisher name

    Institute of Electrical and Electronics Engineers, Inc.

  • Place of publication

  • Event location

    Steasbourg

  • Event date

    Oct 29, 2016

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000432419500411