X-ray Single-Pixel Imaging with MPGD-based detectors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F25%3A00385674" target="_blank" >RIV/68407700:21670/25:00385674 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1088/1748-0221/20/06/P06027" target="_blank" >https://doi.org/10.1088/1748-0221/20/06/P06027</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/20/06/P06027" target="_blank" >10.1088/1748-0221/20/06/P06027</a>
Alternative languages
Result language
angličtina
Original language name
X-ray Single-Pixel Imaging with MPGD-based detectors
Original language description
X-ray imaging is an invaluable tool for noninvasive analysis in many fields ranging from basic science to medicine and security. The development of low-dose large area imaging solutions still represents an important challenge for various applications. One solution to the imaging of large areas lies in the development of novel computational imaging systems that can overcome the limitations imposed by hardware, relying instead on numerical processing power. The single-pixel detector, depending on the application, may offer a competitive edge over conventional cameras (being a cheaper alternative to the multi-pixelated solutions). In addition, the single-pixel detector can be used to achieve improved detection efficiency, faster timing response, and good spatial resolution with low radiation dose. Moreover, this technique enables detectors to image through diffuse mediums, increasing the image quality at significant depths, solving the depth penetration issues of other imaging methods.In this work, we explore the application of single-pixel imaging techniques to produce two-dimensional images with high temporal resolution (only if the process is reproducible and the conditions are static), using only a single detector (bucket detector). The setup, based on the application of Hadamard patterns, showed promising results, proving the ability of the system to acquire images using thin PLA based masks (up to 5 mm thickness). Both simulation, using GEANT 4, and experimental setup, based on a time projection chamber (TPC), used in this work to demonstrate this technique will be reported here along with the first results.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20601 - Medical engineering
Result continuities
Project
<a href="/en/project/GA21-21801S" target="_blank" >GA21-21801S: Measurement of anomalies in angular correlation of electron and positron internally produced in excited 8Be and 4He</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Volume of the periodical
20
Issue of the periodical within the volume
6
Country of publishing house
GB - UNITED KINGDOM
Number of pages
17
Pages from-to
1-17
UT code for WoS article
001515154500001
EID of the result in the Scopus database
2-s2.0-105008987117