International Intercomparison and Quality Assessment of Passive and Active 222Rn Measuring Devices in the Asia-Pacific Region
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70565813%3A_____%2F24%3AN0000008" target="_blank" >RIV/70565813:_____/24:N0000008 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1350448724002439#preview-section-snippets" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1350448724002439#preview-section-snippets</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2024.107295" target="_blank" >10.1016/j.radmeas.2024.107295</a>
Alternative languages
Result language
angličtina
Original language name
International Intercomparison and Quality Assessment of Passive and Active 222Rn Measuring Devices in the Asia-Pacific Region
Original language description
Intercomparison exercise is an integral part of the quality assurance programmes in 222Rn measurements using active and passive devices. Ensuring the accuracy of data generated through measurements necessitates periodic performance checks. To achieve harmonization of methods, quantify biases and errors in measurements, and identify the reasons for discrepancies, there is a pressing need for periodic intercomparison exercises. To address this need of numerous laboratories, particularly in the Asia-Pacific region, a calibration facility for 222Rn measuring devices has been established at the Centre for Advanced Research in Environmental Radioactivity (CARER), Mangalore University, India. An international intercomparison exercise for the 222Rn measuring devices was conducted at this facility in the year 2022 with the participation of 10 laboratories from six countries. A total of 354 devices (comprising of both active and passive detectors) were subjected to intercomparison measurements by exposing them to three concentration levels: (5.97 ± 0.29) × 103 Bq m−3, (0.70 ± 0.09) × 103 Bq m−3 and (2.02 ± 0.20) × 103 Bq m−3 in separate experiments and the exposure durations were 7 days, 15 days, and 10 days respectively. The performance of each laboratory was evaluated following the criterion adopted by the International Atomic Energy Agency (IAEA) in its worldwide proficiency test programmes. This exercise brought out the fact that some of the laboratories need to improve their measurement practices to produce reliable data.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20302 - Applied mechanics
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation Measurements
ISSN
1350-4487
e-ISSN
1879-0925
Volume of the periodical
178
Issue of the periodical within the volume
4
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
12
Pages from-to
—
UT code for WoS article
001320653700001
EID of the result in the Scopus database
2-s2.0-85204187458