Scanning of electromagnetic radiation for EMC and data security purposes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F08%3A63507502" target="_blank" >RIV/70883521:28140/08:63507502 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Scanning of electromagnetic radiation for EMC and data security purposes
Original language description
A semi-automatic measurement system and diagnostic tool for localization of radiating parts of electronic devices in near-field was developed. A near-field scanning of electromagnetic emission is performed by the system. Maximal spatial resolution of thescanning is 0.2 mm which is sufficient for exact localization of radiating parts in the most cases. Frequency range of the measurement is from 30 MHz to 3 GHz. The advantage of the system is simplicity of implementation, as it is based entirely on commercially produced devices. The test receiver Rohde & Schwarz ESPI7 was used for the measurement of radiation level. The advantageous functions of the receiver such as fast frequency scan and simultaneous measurement with three detectors was utilized. Thescanning procedure is controlled by a program which leads a user throughout all measurement steps. The program was made in Agilent VEE Pro. Important part of the measurement is processing of the measured data. Therefore, software for effe
Czech name
Scanning of electromagnetic radiation for EMC and data security purposes
Czech description
A semi-automatic measurement system and diagnostic tool for localization of radiating parts of electronic devices in near-field was developed. A near-field scanning of electromagnetic emission is performed by the system. Maximal spatial resolution of thescanning is 0.2 mm which is sufficient for exact localization of radiating parts in the most cases. Frequency range of the measurement is from 30 MHz to 3 GHz. The advantage of the system is simplicity of implementation, as it is based entirely on commercially produced devices. The test receiver Rohde & Schwarz ESPI7 was used for the measurement of radiation level. The advantageous functions of the receiver such as fast frequency scan and simultaneous measurement with three detectors was utilized. Thescanning procedure is controlled by a program which leads a user throughout all measurement steps. The program was made in Agilent VEE Pro. Important part of the measurement is processing of the measured data. Therefore, software for effe
Classification
Type
D - Article in proceedings
CEP classification
BE - Theoretical physics
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2008
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings 42nd Annual 2008 IEEE International Carnahan Conference on Security Technology
ISBN
978-1-4244-1816-9
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
—
Publisher name
Institute for Electrical and Electronic Engineers, Inc.
Place of publication
New York
Event location
Prague, Czech Republic
Event date
Oct 16, 2008
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—