Cascade Control of a Tubular Chemical Reactor
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F15%3A43873578" target="_blank" >RIV/70883521:28140/15:43873578 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Cascade Control of a Tubular Chemical Reactor
Original language description
The paper presents the cascade control design of a tubular chemical reactor with an exothermic consecutive reaction. The control is performed in primary and secondary control-loops where the primary controlled output of the reactor is the concentration of the main reaction product and the secondary output is the mean temperature of the reactant. A common control input is the coolant flow rate. The controller in the primary control-loop is a P-controller with the gain calculated using simulated or measured steady-state characteristics of the reactor. The controller in the secondary control-loop is an adaptive controller. The proposed method is verified by control simulations.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
BC - Theory and management systems
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the 2015 International Conference on Process Control (PC)
ISBN
978-1-4673-6626-7
ISSN
—
e-ISSN
—
Number of pages
6
Pages from-to
152-157
Publisher name
IEEE Operations Center
Place of publication
Piscataway
Event location
Štrbské Pleso
Event date
Jun 9, 2015
Type of event by nationality
EUR - Evropská akce
UT code for WoS article
—