A rapid and sensitive HPLC method for simultaneous determination of irinotecan hydrochloride and curcumin in co-delivered polymeric nanoparticles
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28610%2F20%3A63526448" target="_blank" >RIV/70883521:28610/20:63526448 - isvavai.cz</a>
Result on the web
<a href="https://academic.oup.com/chromsci/article-abstract/58/7/651/5867553" target="_blank" >https://academic.oup.com/chromsci/article-abstract/58/7/651/5867553</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/chromsci/bmaa033" target="_blank" >10.1093/chromsci/bmaa033</a>
Alternative languages
Result language
angličtina
Original language name
A rapid and sensitive HPLC method for simultaneous determination of irinotecan hydrochloride and curcumin in co-delivered polymeric nanoparticles
Original language description
In recent years, a great deal of attention has been paid to the combined use of multiple antitumor drugs for better cancer treatment. The aims of the study are to construct a nanoparticle drug delivery system for the co-delivery of irinotecan hydrochloride and curcumin and to develop an analytical method for simultaneously quantifying these molecules, which is essential for further studies of the co-delivered nano system. The irinotecan hydrochloride and curcumin co-delivered nanoparticle (ICN) were prepared by combinatorially entrapping them into polyethylene glycol-poly lactic acid-co-glycolic acid (PEG-PLGA) polymeric nanoparticles. A simple, sensitive and rapid high-performance liquid chromatography method was developed and validated to simultaneously quantify the compounds in the co-delivered nanoparticle system. Acetonitrile and ultrapure water containing sodium dodecyl sulfate (0.08 mol/L), disodium phosphate (Na2HPO4, 0.002 mol/L) and acetic acid (4%, v/v) were used as the mobile phase and their ratio was set at 50:50. The flow rate was set to 1.0 mL/min, and the temperature in the column oven was maintained at 40°C. The analysis was carried out at 256 and 424 nm to assess irinotecan hydrochloride and curcumin, respectively. Detectors with only one channel can also visualize both analytes in one chromatogram at 379 nm and still demonstrate acceptable sensitivity. The retention times for irinotecan hydrochloride and curium were 3.317 and 5.560 min, respectively. The method developed was confirmed to be sensitive, accurate (recovery, 100 ± 2%), precise (relative standard deviation, RSD ≤ 1%), robust and linear (R2 ≥ 0.9996) in the range from 2.05 to 1050 μg/mL. The presented method has been used to quantify irinotecan hydrochloride and curcumin in the co-delivered ICN nano system to assess the drug delivery quality of the nanoparticles and can also be used for routine analysis because of its simplicity and accuracy. © The Author(s) 2020. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10404 - Polymer science
Result continuities
Project
<a href="/en/project/LO1504" target="_blank" >LO1504: Centre of Polymer Systems Plus</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of chromatographic science
ISSN
1945-239X
e-ISSN
—
Volume of the periodical
58
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
651-660
UT code for WoS article
000582307300009
EID of the result in the Scopus database
2-s2.0-85088681703