Perceived Indoor Thermal Conditions and Progresive Indoor Technologies
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F17%3A00001116" target="_blank" >RIV/75081431:_____/17:00001116 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.5593/sgem2017/62/S27.090" target="_blank" >http://dx.doi.org/10.5593/sgem2017/62/S27.090</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5593/sgem2017/62/S27.090" target="_blank" >10.5593/sgem2017/62/S27.090</a>
Alternative languages
Result language
angličtina
Original language name
Perceived Indoor Thermal Conditions and Progresive Indoor Technologies
Original language description
Thermal comfort is the condition of mind that expresses satisfaction with complex thermal factors. There are three main factors that can affect the human comfort, which must be considered by engineers before designing progressive indoor technologies; effective temperature, relative humidity and air motion. Building occupants are a rich source of information about indoor environmental quality and its effects on comfort and productivity. Subjective evaluation of indoors is an important part of assessing the quality of the indoor environment. The problems with perceived thermal conditions occur in the buildings using new indoor technologies. Generally it is not easy to arrange good thermal conditions indoors. A large number of people perceive thermal discomfort caused by high or low indoor temperatures. This problem was studied in the selected public building mostly with open space offices. The office buildings broadly are characterized by a large area of glass surfaces, which are significantly affected by external climatic conditions and sunlight. The paper deals with the perceived thermal indoor conditions in the open space offices where the low temperature heating and high temperature cooling were used. The questionnaire for subjective evaluation was used. The questionnaire includes the following parameters: level of indoor acceptability from thermal comfort, air movement, air quality, and air humidity. The thermal conditions were perceived as slightly warm during the winter operation. On the other hand during the summer operation were the conditions perceived as neutral. The other studied parameters were evaluated as acceptable for both periods.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20101 - Civil engineering
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62
ISBN
9786197408133
ISSN
1314-2704
e-ISSN
—
Number of pages
8
Pages from-to
705-712
Publisher name
STEF92 TECHNOLOGY LTD
Place of publication
Sofia (Bulharsko)
Event location
Albena (Bulharsko)
Event date
Jun 29, 2017
Type of event by nationality
CST - Celostátní akce
UT code for WoS article
—