All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Characterization of XR-RV3 GafChromic (R) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F15%3A%230000384" target="_blank" >RIV/86652052:_____/15:#0000384 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1118/1.4922132" target="_blank" >http://dx.doi.org/10.1118/1.4922132</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1118/1.4922132" target="_blank" >10.1118/1.4922132</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Characterization of XR-RV3 GafChromic (R) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

  • Original language description

    XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Medical Physics

  • ISSN

    0094-2405

  • e-ISSN

  • Volume of the periodical

    42

  • Issue of the periodical within the volume

    7

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    16

  • Pages from-to

    4211-4226

  • UT code for WoS article

    000357686400041

  • EID of the result in the Scopus database