Characterization of XR-RV3 GafChromic (R) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F15%3A%230000384" target="_blank" >RIV/86652052:_____/15:#0000384 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1118/1.4922132" target="_blank" >http://dx.doi.org/10.1118/1.4922132</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1118/1.4922132" target="_blank" >10.1118/1.4922132</a>
Alternative languages
Result language
angličtina
Original language name
Characterization of XR-RV3 GafChromic (R) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors
Original language description
XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FS - Medical facilities, apparatus and equipment
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Medical Physics
ISSN
0094-2405
e-ISSN
—
Volume of the periodical
42
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
16
Pages from-to
4211-4226
UT code for WoS article
000357686400041
EID of the result in the Scopus database
—