Measurement of maximum skin dose in interventional radiology and cardiology and challenges in the set-up of European alert thresholds

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F15%3A%230000387" target="_blank" >RIV/86652052:_____/15:#0000387 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1093/rpd/ncu314" target="_blank" >http://dx.doi.org/10.1093/rpd/ncu314</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncu314" target="_blank" >10.1093/rpd/ncu314</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Measurement of maximum skin dose in interventional radiology and cardiology and challenges in the set-up of European alert thresholds

  • Original language description

    To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and on investigating possible correlation to the on-line dose indicators such as fluoroscopy time, Kerma-area product (KAP) and cumulative air Kerma at reference point (CK). The study aims at defining non-centre-specific European alert thresholds for skin dose in three interventional procedures: chemoembolization of the liver (CE), neuroembolization (NE) and percutaneous coronary interventions (PCI). Skin dose values of >3 Gy (ICRP threshold for skin injuries) were indeed measured in these procedures confirming the need for dose indicators that correlate with maximum skin dose (MSD). However, although MSD showed fairly good correlation with KAP and CK, several limitations were identified challenging the set-up of non-centre-specific European alert thresholds. This paper presents preliminary results of this wide European measurement campaign and focuses on the main challenges in the definition of European alert thresholds.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

  • Volume of the periodical

    164

  • Issue of the periodical within the volume

    1-2

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    5

  • Pages from-to

    138-142

  • UT code for WoS article

    000353546100031