Calibration of spectrometric detectors for air kerma rates in environmental monitoring

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F20%3AN0000050" target="_blank" >RIV/86652052:_____/20:N0000050 - isvavai.cz</a>

  • Alternative codes found

    RIV/60162694:G45__/20:00556852

  • Result on the web

    <a href="http://ntrp.vinca.rs/2020_4/Ohera2020_4.html" target="_blank" >http://ntrp.vinca.rs/2020_4/Ohera2020_4.html</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.2298/NTRP2004323O" target="_blank" >10.2298/NTRP2004323O</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Calibration of spectrometric detectors for air kerma rates in environmental monitoring

  • Original language description

    The spectrometric systems, especially based on NaI(Tl) and HPGedetectors, are used for nuclide identification and calculation of their activities from the ground measurements and airborne monitoring. The determination of the air kerma (dose) rates is also very important for environmental measurements. In such cases, the detectors should be calibrated for air kerma (dose) rates in nGyh–1 or µGyh–1. A simple calibration of NaI(Tl), HPGe as well as plastic detectors for the low-level air kerma rates is presented in this contribution. This calibration is based on comparing the relative absorbed energy rate in detectors (MeVs–1) calculated from spectra with the air kerma rates calculated by the Monte Carlo simulation and supplementary to the data from the RSS Reuter&Stokes high pressure ion chamber. This method also eliminates the conversion from the non-air kerma rates in crystals to the air kerma rates. Three different types of small cylindrical detectors were calibrated for the air kerma rates from the background of 26 nGyh–1 to some tens of µGyh–1 in the energy range to the maximum of 3 MeV. The results of calibrations of the 3" x 3" NaI(Tl), HPGe detector and a small plastic detector (made of polystyrene) including some examples of environmental measurements are presented.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10511 - Environmental sciences (social aspects to be 5.7)

Result continuities

  • Project

    <a href="/en/project/VI20172020104" target="_blank" >VI20172020104: The new generation of portal monitors to ensure the security of the population</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Nuclear Technology and Radiation Protection

  • ISSN

    1451-3994

  • e-ISSN

    1452-8185

  • Volume of the periodical

    35

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    RS - THE REPUBLIC OF SERBIA

  • Number of pages

    8

  • Pages from-to

    323-330

  • UT code for WoS article

    000621765200006

  • EID of the result in the Scopus database

    2-s2.0-85103296872