Comparison of luminescence detectors of Al2O3:C, CaF2:Mn, LiF:Mg,Cu,P and quartz with respect to retrospective dose reconstructions using bricks
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F21%3AN0000006" target="_blank" >RIV/86652052:_____/21:N0000006 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0969804321003444" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0969804321003444</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.apradiso.2021.109947" target="_blank" >10.1016/j.apradiso.2021.109947</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of luminescence detectors of Al2O3:C, CaF2:Mn, LiF:Mg,Cu,P and quartz with respect to retrospective dose reconstructions using bricks
Original language description
In the aftermath of an orphan radiation source find, a complex retrospective dose reconstruction can be required to estimate doses of persons who were staying in the vicinity. In retrospective dose reconstructions based on luminescence measurements of quartz extracted from bricks, high sensitivity thermoluminescence detectors (TLD) can be used as an ancillary tool for dose distribution measurements or natural radiation background measurement. We investigated the potential and limits of Al2O3:C, CaF2:Mn and LiF:Mg,Cu,P detectors for such applications. We measured depth-dose profiles in bricks using quartz and the TLDs. We factored in important dosimetry characteristics such as dose response, energy response and detection threshold. The work included Monte Carlo simulations. Depth-dose profiles and radiation spectra inside of the bricks were calculated for purposes of comparison and interpretation. The measurements and calculations were performed for two different photon spectra with mean energies of 662 and 118 keV. As regards comparison of the measured and Monte Carlo calculated depth-dose profiles, the best agreement was found for LiF:Mg,Cu,P. Quartz, Al2O3:C and CaF2:Mn tend to overestimate dose for lower photon energies and greater depths in bricks. The overestimation was the most marked for CaF2:Mn. For measurements related to quartz, especially for natural radiation background dose measurement, the most suitable TLDs are Al2O3:C and LiF:Mg,Cu,P. CaF2:Mn is the least useful material.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10304 - Nuclear physics
Result continuities
Project
<a href="/en/project/VI20192022139" target="_blank" >VI20192022139: Retrospective dosimetry for incidents with orphan radioactive sources</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
1872-9800
Volume of the periodical
178
Issue of the periodical within the volume
December
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
109947
UT code for WoS article
000701739500009
EID of the result in the Scopus database