All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Clinical correlates of B-type natriuretic peptide monitoring in outpatients with left ventricular assist device

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F17%3A00075934" target="_blank" >RIV/00023001:_____/17:00075934 - isvavai.cz</a>

  • Result on the web

    <a href="http://biomed.papers.upol.cz/pdfs/bio/2017/01/09.pdf" target="_blank" >http://biomed.papers.upol.cz/pdfs/bio/2017/01/09.pdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.5507/bp.2017.003" target="_blank" >10.5507/bp.2017.003</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Clinical correlates of B-type natriuretic peptide monitoring in outpatients with left ventricular assist device

  • Original language description

    Background. B-type natriuretic peptide (BNP) is a strong predictor of prognosis in chronic heart failure. We aimed to evaluate the clinical correlates and interpretation of BNP monitoring in LVAD out-patient recipients. Methods. We performed a prospective study in 136 individuals after HeartMate II LVAD implantation. During follow-up they were divided into group A (severe adverse events requiring hospitalisation), group B (mild to moderate adverse events) and group C (an uneventful course). BNP was measured pre-implant, at the first out-patient visit, and then every 2 months. We identified the lowest level, and the level at the clinical event and/or the highest value in patients without clinical events (BNP peak). Results. During a median follow-up of 298 days, 8 patients (6%) died, 21 patients (15%) experienced a severe adverse event (group A) and 38 patients (28%) had other adverse event (group B). Both the absolute value of BNP peak and its percentage values relative to pre-implant, first visit and minimum BNP had similar areas under the curve (AUC) to identify individuals with adverse events (group A and B) from group C. The performance of BNP peak rose from detection of infection to diagnosis of heart failure and culminated in individuals with pump thrombosis (AUC 0.68 vs. 0.75 vs. 0.93). Conclusions. Serial measurement of BNP in outpatients with LVAD correlates with the occurrence of adverse events. Assessment of absolute values of BNP peak seems to have a similar accuracy to analysis of intra-individual variation of BNP and it is more practical.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

    <a href="/en/project/NV15-27682A" target="_blank" >NV15-27682A: Next generation sequencing for early diagnosis and individualized treatment of dilated cardiomyopathy and related forms of cardiomyopathy</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Biomedical papers

  • ISSN

    1213-8118

  • e-ISSN

  • Volume of the periodical

    161

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    7

  • Pages from-to

    68-74

  • UT code for WoS article

    000398093500010

  • EID of the result in the Scopus database