All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Methods for Removing of Line Noise Artifact from EEG Records with Minimization of Neural Information Loss

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023752%3A_____%2F20%3A43920117" target="_blank" >RIV/00023752:_____/20:43920117 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21460/20:00336907

  • Result on the web

    <a href="https://link.springer.com/chapter/10.1007%2F978-3-030-31635-8_22" target="_blank" >https://link.springer.com/chapter/10.1007%2F978-3-030-31635-8_22</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/978-3-030-31635-8_22" target="_blank" >10.1007/978-3-030-31635-8_22</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Methods for Removing of Line Noise Artifact from EEG Records with Minimization of Neural Information Loss

  • Original language description

    Line noise is artifact affecting a gamma band of the EEG. Conventional filters are used for removing the line noise artifact, but these filters, also remove physiological activity and could induce spurious oscillations. We tested two alternative methods for removing line noise artifact without removing a physiological activity, specifically Adaptive noise cancellation (ANC) method with Linear regression and modified Independent Component Analysis (ICA). We proposed a new protocol for statistical evaluation of line noise removal effectiveness. The line noise artifact was physically simulated and the protocol for statistical evaluation was verified. The ANC method shows good results according to statistical evaluation. The lowest residuum of simulated line noise artifact corresponds to 0.0005 Hz. Nevertheless, the ANC is very sensitive to the quality of the reference signal, which heavily depends on the reference electrode selection.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019; Coimbra; Portugal; 26 September 2019 through 28 September 2019

  • ISBN

    978-3-030-31634-1

  • ISSN

    1680-0737

  • e-ISSN

  • Number of pages

    9

  • Pages from-to

    184-192

  • Publisher name

    Springer Nature

  • Place of publication

    Switzerland

  • Event location

    Coimbra, Portugal

  • Event date

    Sep 26, 2019

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article