Determination of cysteinyl leukotrienes in exhaled breath condensate: Method combining immunoseparation with LC-ESI-MS/MS
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F11%3A9595" target="_blank" >RIV/00064165:_____/11:9595 - isvavai.cz</a>
Alternative codes found
RIV/60461373:22310/11:43891926 RIV/60461373:22330/11:43891926 RIV/60461373:22330/11:43892670 RIV/60461373:22310/11:43892670 and 2 more
Result on the web
<a href="http://dx.doi.org/10.1016/j.jchromb.2011.06.004" target="_blank" >http://dx.doi.org/10.1016/j.jchromb.2011.06.004</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Determination of cysteinyl leukotrienes in exhaled breath condensate: Method combining immunoseparation with LC-ESI-MS/MS
Original language description
A rapid and precise method for the identification and quantification of cysteinyl leukotrienes (leukotriene C(4), leukotriene D(4) and leukotriene E(4)), essential markers of bronchial asthma, in exhaled breath condensate was developed. The protocol consists of immunoaffinity separation and a detection step, liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). In particular, the selected reaction monitoring mode was used for its extremely high degree of selectivity and the stable-isotope-dilution assay for its high precision of quantification. The developed method was characterized with a high precision (<= 7.7%, determined as RSD), an acceptable accuracy (90.4-93.7%, determined as recovery), a low limitof detection (<= 2 pg/ml EBC) and a low limit of quantification (<= 10 pg/ml EBC). It was compared to other simple, clinically appropriate combinations of pre-treatment methods (solid phase extraction and lyophilization) with LC/MS. Final
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FE - Other fields of internal medicine
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography B
ISSN
1570-0232
e-ISSN
—
Volume of the periodical
879
Issue of the periodical within the volume
23
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
9
Pages from-to
2220-2228
UT code for WoS article
000293722800007
EID of the result in the Scopus database
—