Correlation between transversal and orthogonal maximal diameters of abdominal aortic aneurysms and alternative rupture risk predictors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00067195" target="_blank" >RIV/00159816:_____/17:00067195 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26210/17:PU122974 RIV/00216224:14110/17:00097641 RIV/00216208:11110/17:10362321 RIV/00064165:_____/17:10362321
Result on the web
<a href="http://dx.doi.org/10.1016/j.compbiomed.2017.03.005" target="_blank" >http://dx.doi.org/10.1016/j.compbiomed.2017.03.005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.compbiomed.2017.03.005" target="_blank" >10.1016/j.compbiomed.2017.03.005</a>
Alternative languages
Result language
angličtina
Original language name
Correlation between transversal and orthogonal maximal diameters of abdominal aortic aneurysms and alternative rupture risk predictors
Original language description
Purpose: There is no standard for measuring maximal diameter (Dmax) of abdominal aortic aneurysm (AAA) from computer tomography (CT) images although differences between Dmax evaluated from transversal (axialDmax) or orthogonal (orthoDmax) planes can be large especially for angulated AAAs. Therefore we investigated their correlations with alternative rupture risk indicators as peak wall stress (PWS) and peak wall rupture risk (PWRR) to decide which Dmax is more relevant in AAA rupture risk assessment. Material and methods: The Dmax values were measured by a trained radiologist from 70 collected CT scans, and the corresponding PWS and PWRR were evaluated using Finite Element Analysis (FEA). The cohort was ordered according to the difference between axialDmax and orthoDmax (Da-o) quantifying the aneurysm angulation, and Spearman's correlation coefficients between PWS/PWRR orthoDmax/axialDmax were calculated. Results: The calculated correlations PWS/PWRR vs. orthoDmax were substantially higher for angulated AAAs (with Da-o >= 3mm). Under this limit, the correlations were almost the same for both Dmax values. Analysis of AAAs divided into two groups of angulated (n=38) and straight (n=32) cases revealed that both groups are similar in all parameters (orthoDmax, PWS, PWRR) with the exception of axialDmax (p=0.024). Conclusions: It was confirmed that orthoDmax is better correlated with the alternative rupture risk predictors PWS and PWRR for angulated AAA5 (DA-O >= 3mm) while there is no difference between orthoDmax and axialDmax for straight AAAs (DA-O<3mm). As angulated AAA5 represent a significant portion of cases it can be recommended to use orthoDmax as the only Dmax parameter for AAA rupture risk assessment.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30212 - Surgery
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Computers in Biology and Medicine
ISSN
0010-4825
e-ISSN
—
Volume of the periodical
83
Issue of the periodical within the volume
APR 1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
151-156
UT code for WoS article
000399862200015
EID of the result in the Scopus database
—