All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Final publishable report from 18NRM02 PRISM-eBT

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F23%3AN0000079" target="_blank" >RIV/00177016:_____/23:N0000079 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Final publishable report from 18NRM02 PRISM-eBT

  • Original language description

    Electronic brachytherapy (eBT) is a cost-effective radiotherapeutic modality for the treatment of skin lesions, intraoperative partial breast irradiation, intracavitary and interstitial sites, brain tumours and kypho- Intraoperative Radiotherapy (IORT). While it offers potential for an extensive utilisation, this is unlikely to be achieved whilst eBT systems rely on individual calibration procedures. In most cases these systems are not directly traceable to NMIs and rely on indirect calibration methods with uncertainties larger than clinically acceptable. This project delivered a harmonised, simplified and traceable dosimetry for eBT, detectors and measurement devices for the determination of 3D dose distributions in water, to ensure that these systems can achieve their full clinical potential. During the project several primary realizations were established for both intercavitary and superficial treatment. (obj 1 &2). Standardized traceable calibration process for 3D detectors were established (obj 3) to provide traceable dosimetry for 3D dose distribution measurements (obj.4). Contribution to standard developing organizations were performed.

  • Czech name

  • Czech description

Classification

  • Type

    V<sub>souhrn</sub> - Summary research report

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

    <a href="/en/project/8B19003" target="_blank" >8B19003: Primary standards and traceable measurement methods for X-ray emitting electronic brachytherapy devices</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Number of pages

    22

  • Place of publication

    PTB Branschweig, Německo

  • Publisher/client name

    EURAMET

  • Version