Cardiac doses with deep inspiration breath hold in breast cancer radiotherapy: direct comparison between WBI, PBI, and interstitial APBI
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F24%3A10483905" target="_blank" >RIV/00179906:_____/24:10483905 - isvavai.cz</a>
Alternative codes found
RIV/60162694:G44__/25:00563642 RIV/00216208:11150/24:10483905
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Z1UHOhkr4L" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Z1UHOhkr4L</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5603/rpor.99907" target="_blank" >10.5603/rpor.99907</a>
Alternative languages
Result language
angličtina
Original language name
Cardiac doses with deep inspiration breath hold in breast cancer radiotherapy: direct comparison between WBI, PBI, and interstitial APBI
Original language description
Background: The optimal radiotherapy technique for cardiac sparing in left-sided early breast cancer (EBC) is not clear. In this context, the aim of our dosimetric study was to compare cardiac and lung doses according to the type of radiotherapy - whole breast irradiation (WBI), external partial breast irradiation (PBI), and multicatheter interstitial brachytherapy-accelerated partial breast irradiation (MIB-APBI). The dosimetric results with the WBI and PBI were calculated with and without DIBH. Materials and methods: Dosimetric study of 23 patients treated with WBI, PBI, with and without DIBH, or MIB-APBI. The prescribed dose was 40 Gy in 15 fractions for WBI and PBI and 34 Gy in 10 fractions (bid) for MIB-APBI. Doses to the organs-at-risk (OAR) - heart, left anterior descending coronary artery (LAD), left ventricle (LV), and left lung - were recalculated to the equivalent dose in 2-Gy fractions (EQD2). Results: The addition of DIBH significantly reduced EQD2 doses to all OARs (except for the left lung maximal dose) in WBI and PBI. MHD values were 0.72 Gy for DIBH-WBI, 1.01 Gy for MIB-APBI and 0.24 Gy for DIBH-PBI. There were no significant differences in cardiac doses between WBI with DIBH and PBI without DIBH. DIBH-PBI resulted in significantly lower mean doses to all OARs (except for maximum lung dose) compared to MIB-APBI. Conclusions: These results show that the use of DIBH significantly reduces cardiac doses in patients with left EBC. Partial irradiation techniques (PBI, MIB-APBI) significantly reduced cardiac doses due to the smaller clinical target volume. The best results were obtained with DIBH-PBI.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Reports of Practical Oncology and Radiotherapy
ISSN
1507-1367
e-ISSN
2083-4640
Volume of the periodical
29
Issue of the periodical within the volume
2
Country of publishing house
PL - POLAND
Number of pages
9
Pages from-to
155-163
UT code for WoS article
001288903000001
EID of the result in the Scopus database
2-s2.0-85196316657