Magnetic resonance angiography, digital subtraction angiography and Doppler ultrasonography in detection of carotid artery stenosis: a comparison with findings from histological specimens
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F10%3A6299" target="_blank" >RIV/00216208:11110/10:6299 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/10:00002434
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Magnetic resonance angiography, digital subtraction angiography and Doppler ultrasonography in detection of carotid artery stenosis: a comparison with findings from histological specimens
Original language description
Patients' life expectancy, clinical symptomatology and the extent of carotid stenosis are the most important factors when deciding whether to perform carotid endarterectomy (CEA) in patients with carotid stenosis. Therefore, the accuracy of measuring carotid stenosis is of utmost importance. Patients with internal carotid artery (ICA) stenosis were investigated by digital subtraction angiography (DSA), Doppler ultrasonography (DUS) and magnetic resonance angiography (MRA). Atherosclerotic plaque specimens were transversally cut into smaller segments and histologically processed. The slides were scanned and specimens showing maximal stenosis were determined; the minimal diameter and the diameter of the whole plaque were measured. DSA, DUS and MRA measurements were obtained in 103 patients. A comparison between preoperative and histological findings was performed. In addition, correlation coefficients were computed and tested. Results show a significant correlation for each of the diagno
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FH - Neurology, neuro-surgery, nuero-sciences
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/NR9435" target="_blank" >NR9435: Correlation of MR angiography, Doppler ultrasonography and Digital Subtraction Angiography with Histological Specimen of Carotid Stenosis</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta neurochirurgica
ISSN
0001-6268
e-ISSN
—
Volume of the periodical
152
Issue of the periodical within the volume
7
Country of publishing house
AT - AUSTRIA
Number of pages
7
Pages from-to
—
UT code for WoS article
000278922300016
EID of the result in the Scopus database
—