Can the Gold Standard Be Beaten? How Reliable Are Various Modifications of the Synacthen Test Compared to the Insulin Tolerance Test
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10363748" target="_blank" >RIV/00216208:11110/17:10363748 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/17:43915708 RIV/00023761:_____/17:N0000038 RIV/00064173:_____/17:N0000112 RIV/00064165:_____/17:10363748
Result on the web
<a href="http://www.biomed.cas.cz/physiolres/pdf/66/66_S387.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/66/66_S387.pdf</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Can the Gold Standard Be Beaten? How Reliable Are Various Modifications of the Synacthen Test Compared to the Insulin Tolerance Test
Original language description
Criteria for the evaluation of the insulin tolerance test (ITT) and Synacthen test are still a matter of debate. The objective of the study was to make a comparison of serum and salivary cortisol during four stimulation tests. Sixty four healthy volunteers underwent the ITT, the Synacthen test with 1 (LDST), 10 (MDST) and 250 (HDST)μg dose of ACTH. Maximum serum cortisol response was observed at the 90 min of the ITT (49 %), HDST(89 %) and MDST (56 %) and at the 40 min of the LDST (44 %). Results expressed as 95 % confidence intervals: 408.0-843.6 and 289.5-868.1 nmol/l in the IIT at 60 and 90 min. In the HDST and the MDST serum cortisol reached the maximum at 90 min 542.6- 1245.5 and 444.2-871.3 nmol/l. Levels of salivary cortisol followed the same pattern as serum cortisol. Salivary cortisol reached the maximum response in the HDST and the MDST at 90 min and at 40 min in the LDST. We confirmed good reliability of all tests with respect to timing of response and maximum response compared to the ITT. We proved that the MDST test can provide the similar response in serum cortisol to the HDST. Measuring either salivary cortisol or ACTH levels did not provide any additional benefit then measuring serum cortisol by itself.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30202 - Endocrinology and metabolism (including diabetes, hormones)
Result continuities
Project
<a href="/en/project/NT11277" target="_blank" >NT11277: Standardization of dynamic tests of hypocorticalism</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physiological Research
ISSN
0862-8408
e-ISSN
—
Volume of the periodical
66
Issue of the periodical within the volume
Suppl. 3
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
9
Pages from-to
387-395
UT code for WoS article
000412737900013
EID of the result in the Scopus database
—