Diagnostic Accuracy of Dobutamine Stress Echocardiography for Detection of Cardiac Allograft Vasculopathy in Orthotopic Heart Transplant Patients
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F21%3A10438729" target="_blank" >RIV/00216208:11110/21:10438729 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/21:10438729
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ZkcorXSFXR" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=ZkcorXSFXR</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.37616/2212-5043.1265" target="_blank" >10.37616/2212-5043.1265</a>
Alternative languages
Result language
angličtina
Original language name
Diagnostic Accuracy of Dobutamine Stress Echocardiography for Detection of Cardiac Allograft Vasculopathy in Orthotopic Heart Transplant Patients
Original language description
Objective: Cardiac allograft vasculopathy is one of the leading causes of late graft failure and subsequent death in orthotopic heart transplant. Although invasive coronary angiography is the gold standard modality for detection of cardiac allograft vasculopathy, dobutamine stress echocardiography has been recently frequently used as an alternative. Our aim was to evaluate the diagnostic performance of dobutamine stress echocardiography for detection of cardiac allograft vasculopathy in transplant patients. Methods: A retrospective analysis was conducted using a total of 150 dobutamine stress echocardiographic exams that were performed on 99 patients in our institution, with paired coronary angiogram and no acute rejection, within a median of 538 [interquartile range 371-816] days. Sensitivity and specificity of dobutamine echocardiography to detect allograft vasculopathy was evaluated. Allograft vasculopathy was defined as Grade 1 or higher based on ISHLT criteria. A positive dobutamine stress echo result was defined by new or worsening wall motion abnormality. Results: Median age of the population at transplant was 34 [interquartile range 22-46] years; 76 (77%) patients were male. Allograft vasculopathy was present in 31 (20.6%) out of 150 coronary angiograms. Only 7 (4.6%) of that number were positive on dobutamine stress echocardiography. Sensitivity and specificity for allograft vasculopathy detection was 3% and 94%, respectively. Out of 7 false positive dobutamine stress echocardiograms, two were in patients with myocardial bridging. Two patients with mild acute rejection had both negative dobutamine stress echo. Conclusions: Overall, positivity of dobutamine stress echocardiography in patients after heart transplant is low. It has high specificity, but very low sensitivity for detection of cardiac allograft vasculopathy. Dobutamine stress echocardiography should only be cautiously used as an alternative to coronary angiography.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of the Saudi Heart Association
ISSN
1016-7315
e-ISSN
—
Volume of the periodical
33
Issue of the periodical within the volume
4
Country of publishing house
SA - THE KINGDOM OF SAUDI ARABIA
Number of pages
7
Pages from-to
279-285
UT code for WoS article
000749848500007
EID of the result in the Scopus database