All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

A multicentre study on unattended automated office blood pressure measurement in treated hypertensive patients

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F18%3A10380827" target="_blank" >RIV/00216208:11140/18:10380827 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216224:14110/18:00103952 RIV/65269705:_____/18:00068809 RIV/00179906:_____/18:10380827 RIV/00669806:_____/18:10380827 RIV/00159816:_____/18:00068809

  • Result on the web

    <a href="https://doi.org/10.1080/08037051.2018.1425606" target="_blank" >https://doi.org/10.1080/08037051.2018.1425606</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1080/08037051.2018.1425606" target="_blank" >10.1080/08037051.2018.1425606</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A multicentre study on unattended automated office blood pressure measurement in treated hypertensive patients

  • Original language description

    Aims: Unattended automated office blood pressure (uAutoOBP) may eliminate white-coat effect. In the present study, we studied its relationships to attended office blood pressure (BP) and ambulatory BP monitoring (ABPM).Material and methods: Stable treated hypertensive subjects were examined in four Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP was measured six times: three times with auscultatory method (AuscOBP) by the physician followed optionally by three oscillometric measurements (OscOBP). ABPM was performed within one week from the clinical visit.Results: Data on 172 subjects aged 63.712.4 years with AuscOBP 127.6 +/- 12.1/77.6 +/- 10.0mm Hg are reported. uAutoOBP was by 8.5 +/- 9.0/3.0 +/- 6.1mm Hg lower than AuscOBP. The AuscOBP-uAutoOBP difference increased with the AuscOBP level and it did not depend on any other factor. OscOBP differed by 8.6 +/- 8.6/1.9 +/- 5.7mm Hg from uAutoOBP. 24-hour mean BP was by 4.2 +/- 12.1/3.5 +/- 7.8mm Hg lower than AuscOBP and by 4.3 +/- 11.0/0.5 +/- 6.9mm Hg higher than uAutoOBP; the correlation coefficients of 24-hour mean BP with AuscOBP and with uAutoOBP did not differ (p for difference.13). In the lowest BP group (systolic AuscOBP&lt;120mm Hg or diastolic AuscOBP&lt;70mm Hg), both AuscOBP and uAutoOBP were lower than 24-hour mean BP, while in the highest BP group (systolic AuscOBP140mm Hg or diastolic AuscOBP90mm Hg), they were higher.Conclusions: Compared to uAutoOBP, attended BP measurement gives higher values, both when measured with auscultatory or oscillometric method. Inter-individual variability of AutoOBP - uAuscOBP difference, as well of uAutoOBP - ABPM difference, is large. We did not prove that uAutoOBP would be associated to 24-hour ambulatory BP more closely than attended BP.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Blood Pressure

  • ISSN

    0803-7051

  • e-ISSN

  • Volume of the periodical

    27

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    6

  • Pages from-to

    188-193

  • UT code for WoS article

    000437328100002

  • EID of the result in the Scopus database

    2-s2.0-85041123941