A multicentre study on unattended automated office blood pressure measurement in treated hypertensive patients
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F18%3A10380827" target="_blank" >RIV/00216208:11140/18:10380827 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/18:00103952 RIV/65269705:_____/18:00068809 RIV/00179906:_____/18:10380827 RIV/00669806:_____/18:10380827 RIV/00159816:_____/18:00068809
Result on the web
<a href="https://doi.org/10.1080/08037051.2018.1425606" target="_blank" >https://doi.org/10.1080/08037051.2018.1425606</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/08037051.2018.1425606" target="_blank" >10.1080/08037051.2018.1425606</a>
Alternative languages
Result language
angličtina
Original language name
A multicentre study on unattended automated office blood pressure measurement in treated hypertensive patients
Original language description
Aims: Unattended automated office blood pressure (uAutoOBP) may eliminate white-coat effect. In the present study, we studied its relationships to attended office blood pressure (BP) and ambulatory BP monitoring (ABPM).Material and methods: Stable treated hypertensive subjects were examined in four Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP was measured six times: three times with auscultatory method (AuscOBP) by the physician followed optionally by three oscillometric measurements (OscOBP). ABPM was performed within one week from the clinical visit.Results: Data on 172 subjects aged 63.712.4 years with AuscOBP 127.6 +/- 12.1/77.6 +/- 10.0mm Hg are reported. uAutoOBP was by 8.5 +/- 9.0/3.0 +/- 6.1mm Hg lower than AuscOBP. The AuscOBP-uAutoOBP difference increased with the AuscOBP level and it did not depend on any other factor. OscOBP differed by 8.6 +/- 8.6/1.9 +/- 5.7mm Hg from uAutoOBP. 24-hour mean BP was by 4.2 +/- 12.1/3.5 +/- 7.8mm Hg lower than AuscOBP and by 4.3 +/- 11.0/0.5 +/- 6.9mm Hg higher than uAutoOBP; the correlation coefficients of 24-hour mean BP with AuscOBP and with uAutoOBP did not differ (p for difference.13). In the lowest BP group (systolic AuscOBP<120mm Hg or diastolic AuscOBP<70mm Hg), both AuscOBP and uAutoOBP were lower than 24-hour mean BP, while in the highest BP group (systolic AuscOBP140mm Hg or diastolic AuscOBP90mm Hg), they were higher.Conclusions: Compared to uAutoOBP, attended BP measurement gives higher values, both when measured with auscultatory or oscillometric method. Inter-individual variability of AutoOBP - uAuscOBP difference, as well of uAutoOBP - ABPM difference, is large. We did not prove that uAutoOBP would be associated to 24-hour ambulatory BP more closely than attended BP.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Blood Pressure
ISSN
0803-7051
e-ISSN
—
Volume of the periodical
27
Issue of the periodical within the volume
4
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
188-193
UT code for WoS article
000437328100002
EID of the result in the Scopus database
2-s2.0-85041123941