Fast HPLC Method for Determination of Fenoxycarb and Permethrin in Antiparasitic Veterinary Shampoo Using Fused-Core Column
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F13%3A10146040" target="_blank" >RIV/00216208:11160/13:10146040 - isvavai.cz</a>
Result on the web
<a href="http://link.springer.com/article/10.1007/s10337-013-2464-0/fulltext.html" target="_blank" >http://link.springer.com/article/10.1007/s10337-013-2464-0/fulltext.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10337-013-2464-0" target="_blank" >10.1007/s10337-013-2464-0</a>
Alternative languages
Result language
angličtina
Original language name
Fast HPLC Method for Determination of Fenoxycarb and Permethrin in Antiparasitic Veterinary Shampoo Using Fused-Core Column
Original language description
A new and fast high-performance liquid chromatography (HPLC) method using technology of fused-core columns for separation of fenoxycarb and cis-, trans-permethrin has been developed and used for their determination in antiparasitic veterinary shampoo. Separation of insecticides and internal standard sudan II was achieved on the fused-core column Ascentis Express RP-Amide (100 x 3.0 mm), particle size 2.7 mu m, with mobile phase acetonitrile/water (55:45, v/v) at a flow rate of 1.0 mL min(-1) and at temperature 60 A degrees C. The detection wavelength of detector was set at 225 nm for both compounds and internal standard sudan II. Under the optimum chromatographic conditions standard calibration curves were measured with good linearity [r (2) = 0.99991for fenoxycarb, r (2) = 0.99987 for trans-permethrin, and r (2) = 0.99984 for cis-permethrin (n = 8)]. Commercial samples of antiparasitic veterinary shampoo were extracted with ethanol in ultrasound bath for 5 min. A 2-mu L sample volume
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Chromatographia
ISSN
0009-5893
e-ISSN
—
Volume of the periodical
76
Issue of the periodical within the volume
21-22
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
6
Pages from-to
1559-1564
UT code for WoS article
000326118900018
EID of the result in the Scopus database
—