All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Amperometric Determination of Catecholamines by Enzymatic Biosensors in Flow Systems

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F18%3A10376275" target="_blank" >RIV/00216208:11310/18:10376275 - isvavai.cz</a>

  • Alternative codes found

    RIV/61388955:_____/18:00490697

  • Result on the web

    <a href="https://doi.org/10.1002/elan.201800078" target="_blank" >https://doi.org/10.1002/elan.201800078</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elan.201800078" target="_blank" >10.1002/elan.201800078</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Amperometric Determination of Catecholamines by Enzymatic Biosensors in Flow Systems

  • Original language description

    Four various biosensors based on flow enzymatic mini-reactors containing one of the two different mesoporous silica powders (SBA-15 or MCM-41) modified by one of the two enzymes (laccase or tyrosinase) were used for the determination of L-DOPA, dopamine, noradrenaline, and adrenaline. Dependences of peak currents on detection potentials, flow rates, injected volumes, reactor volumes, and analyte concentrations were studied and optimized. The silica powder of MCM-41 with covalently bonded laccase (Lac) was found to be the best filling for the detection of catecholamines. Relative current response of such biosensor was: 100% for dopamine, 32.1% for L-DOPA, 26.2% for noradrenaline, and 0.71% for adrenaline. Statistical evaluation of parallel determinations of studied analytes with this biosensor proved its good accuracy (RSD=1.82-5.18%) and sensitivity (5.46-15.5molL(-1)). Life time of the studied biosensors is several months. The practical applicability of Lac-MCM41 biosensor was successfully verified by the determination of dopamine and noradrenaline in medical solutions for infusions.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electroanalysis

  • ISSN

    1040-0397

  • e-ISSN

  • Volume of the periodical

    30

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    9

  • Pages from-to

    1163-1171

  • UT code for WoS article

    000435271000026

  • EID of the result in the Scopus database

    2-s2.0-85043703846