A new green approach to L-histidine and β-alanine analysis in dietary supplements using rapid and simple contactless conductivity detection integrated with high-resolution glass-microchip electrophoresis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F24%3A10495989" target="_blank" >RIV/00216208:11310/24:10495989 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=m7rwx~iaJn" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=m7rwx~iaJn</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-024-05314-9" target="_blank" >10.1007/s00216-024-05314-9</a>
Alternative languages
Result language
angličtina
Original language name
A new green approach to L-histidine and β-alanine analysis in dietary supplements using rapid and simple contactless conductivity detection integrated with high-resolution glass-microchip electrophoresis
Original language description
The analysis of dietary supplements is far less regulated than pharmaceuticals, leading to potential quality issues. Considering their positive effect, many athletes consume supplements containing L-histidine and β-alanine. A new microfluidic method for the determination of L-histidine and β-alanine in dietary supplement formulations has been developed. For the first time, capacitively coupled contactless conductivity detection was employed for the microchip electrophoresis of amino acids in real samples. A linear relationship between detector response and concentration was observed in the range of 10-100 µmol L(-1) for L-histidine (R(2) = 0.9968) and β-alanine (R(2) = 0.9954), while achieved limits of detection (3 x S/N ratio) were 4.2 µmol L(-1) and 5.2 µmol L(-1), respectively. The accuracy of the method was confirmed using recovery experiments as well as CE-UV-VIS and HPLC-UV-VIS techniques. The developed method allows unambiguous identification of amino acids in native form without chemical derivatization and with the possibility of simultaneous analysis of amino acids with metal cations.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
1618-2650
Volume of the periodical
416
Issue of the periodical within the volume
15
Country of publishing house
DE - GERMANY
Number of pages
13
Pages from-to
3605-3617
UT code for WoS article
001220199300001
EID of the result in the Scopus database
2-s2.0-85192387742