Comparison of Metal Nanoparticles (Au, Ag, Eu, Cd) Used for Immunoanalysis Using LA-ICP-MS Detection
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14110%2F21%3A00119608" target="_blank" >RIV/00216224:14110/21:00119608 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/21:PU140507 RIV/62156489:43210/21:43919348 RIV/00209805:_____/21:00078547
Result on the web
<a href="https://www.mdpi.com/1420-3049/26/3/630" target="_blank" >https://www.mdpi.com/1420-3049/26/3/630</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/molecules26030630" target="_blank" >10.3390/molecules26030630</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of Metal Nanoparticles (Au, Ag, Eu, Cd) Used for Immunoanalysis Using LA-ICP-MS Detection
Original language description
Immunochemical methods are used not only in clinical practice for the diagnosis of a wide range of diseases but also in basic and advanced research. Based on the unique reaction between the antibody and its respective antigens, it serves to specifically recognize target molecules in biological complex samples. Current methods of labelling antibodies with elemental labels followed by detection by inductively coupled plasma mass spectrometry (ICP-MS) allow detection of multiple antigens in parallel in a single analysis. Using the laser ablation (LA) modality (LA-ICP-MS), it is also possible to monitor the spatial distribution of biogenic elements. Moreover, the employment of metal nanoparticle-labeled antibodies expands the applicability also to molecular imaging by LA-ICP-MS. In this work, conjugates of model monoclonal antibody (DO-1, recognizing p53 protein) with various metal nanoparticles-based labels were created and utilized in dot-blot analysis in order to compare their benefits and disadvantages. Based on experiments with the p53 protein standard, commercial kits of gold nanoparticles proved to be the most suitable for the preparation of conjugates. The LA-ICP-MS demonstrated very good repeatability, wide linear dynamic range (0.1-14 ng), and limit of detection was calculated as a 1.3 pg of p53 protein.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10608 - Biochemistry and molecular biology
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Molecules
ISSN
1420-3049
e-ISSN
1420-3049
Volume of the periodical
26
Issue of the periodical within the volume
3
Country of publishing house
CH - SWITZERLAND
Number of pages
11
Pages from-to
1-11
UT code for WoS article
000615460400001
EID of the result in the Scopus database
2-s2.0-85101239243