All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Comparison of metal nanoparticles (Au, Ag, Eu, Cd) used for immunoanalysis using LA-ICP-MS detection

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F21%3APU140507" target="_blank" >RIV/00216305:26620/21:PU140507 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216224:14110/21:00119608 RIV/62156489:43210/21:43919348 RIV/00209805:_____/21:00078547

  • Result on the web

    <a href="https://www.mdpi.com/1420-3049/26/3/630" target="_blank" >https://www.mdpi.com/1420-3049/26/3/630</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/molecules26030630" target="_blank" >10.3390/molecules26030630</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Comparison of metal nanoparticles (Au, Ag, Eu, Cd) used for immunoanalysis using LA-ICP-MS detection

  • Original language description

    Immunochemical methods are used not only in clinical practice for the diagnosis of a wide range of diseases but also in basic and advanced research. Based on the unique reaction between the antibody and its respective antigens, it serves to specifically recognize target molecules in biological complex samples. Current methods of labelling antibodies with elemental labels followed by detection by inductively coupled plasma mass spectrometry (ICP-MS) allow detection of multiple antigens in parallel in a single analysis. Using the laser ablation (LA) modality (LA-ICP-MS), it is also possible to monitor the spatial distribution of biogenic elements. Moreover, the employment of metal nanoparticle-labeled antibodies expands the applicability also to molecular imaging by LA-ICP-MS. In this work, conjugates of model monoclonal antibody (DO-1, recognizing p53 protein) with various metal nanoparticles-based labels were created and utilized in dot-blot analysis in order to compare their benefits and disadvantages. Based on experiments with the p53 protein standard, commercial kits of gold nanoparticles proved to be the most suitable for the preparation of conjugates. The LA-ICP-MS demonstrated very good repeatability, wide linear dynamic range (0.1-14 ng), and limit of detection was calculated as a 1.3 pg of p53 protein.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    MOLECULES

  • ISSN

    1420-3049

  • e-ISSN

  • Volume of the periodical

    26

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    14

  • Pages from-to

    246-259

  • UT code for WoS article

    000615460400001

  • EID of the result in the Scopus database