Piezoelectric biosensors for real-time monitoring of hybridization and detection of the hepatitis C virus
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F04%3A00010106" target="_blank" >RIV/00216224:14310/04:00010106 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Piezoelectric biosensors for real-time monitoring of hybridization and detection of the hepatitis C virus
Original language description
The piezoelectric quartz crystal resonators modified with oligonucleotide probes were used for detection of hepatitis C virus in serum. The gold electrodes on either rough or smooth surface crystals were modified with a self-assembled monolayer of cystamine. After activation with glutaraldehyde, either avidin or streptavidin were immobilized and used for attachment of biotinylated DNA probes (4 different sequences). Thus prepared piezoelectric biosensors were used in a flow-through setup for direct monitoring of DNA resulting from the reverse transcriptase linked polymerase chain reaction (RT-PCR) amplification of the original viral RNA. The samples of patients with hepatitis C were analyzed and the results were compared with the standard RT-PCR procedure (Amplicor test kit of Roche, microwell format with spectrophotometric evaluation). The piezoelectric hybridization assay was completed in 10 min and the same sensing surface was suitable for repeated use.
Czech name
Piezoelektrický biosensor pro sledování hybridizace v reálném čase a pro stanovení viru hepatitidy C
Czech description
Piezoelektrický krystalový resonátor byl modifikován oligonukleotidovou probou a použit pro detekci virové nukleové kyseliny v seru. Biotinylované proby byly navázany na monovrstvu avidinu kovalentně vázanou na povrch zlatých elektrod. Virová RNA byla pomocí RT-PCR techniky převedena na DNA, které pak byly detekovány PZ biosensorem. Pro srovnání byly vzorky analyzovány také soupravou Amplicor firmy Roche (fotometrické stanovení na mikrodestičce).
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CE - Biochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/OC%20518.30" target="_blank" >OC 518.30: Characterization of interactions of biomacromolecules with biolayers in different conformation states using piezoelectric biosensors</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2004
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Virological Methods
ISSN
0166-0934
e-ISSN
—
Volume of the periodical
117
Issue of the periodical within the volume
2
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
7