Harmonized Quality Assurance/Quality Control Provisions for Nontargeted Measurement of Urinary Pesticide Biomarkers in the HBM4EU Multisite SPECIMEn Study

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F22%3A00126753" target="_blank" >RIV/00216224:14310/22:00126753 - isvavai.cz</a>

  • Result on the web

    <a href="https://pubs.acs.org/doi/10.1021/acs.analchem.2c00061" target="_blank" >https://pubs.acs.org/doi/10.1021/acs.analchem.2c00061</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1021/acs.analchem.2c00061" target="_blank" >10.1021/acs.analchem.2c00061</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Harmonized Quality Assurance/Quality Control Provisions for Nontargeted Measurement of Urinary Pesticide Biomarkers in the HBM4EU Multisite SPECIMEn Study

  • Original language description

    A set of quality assurance/quality control (QA/QC) criteria for nontargeted measurement of pesticide exposure markers in a large-scale study of human urine has been proposed and applied across five laboratories within the HBM4EU project. Quality control material, including reference standards and fortified pooled urine samples (QC urine) were prepared in a centralized way and distributed across participants to monitor analytical performance and consistency of the liquid chromatography coupled to high-resolution mass spectrometry data generated with a harmonized workflow. Signal intensities, mass accuracy, and retention times of selected QA/QC markers covering a broad range of physicochemical properties were monitored across QC solvent standards, QC urine samples, study urine samples, and procedural blanks, setting acceptance thresholds for repeatability and accuracy. Overall, results showed high repeatability of the collected data. The RSDs of the signal intensities were typically below 20-30% in QC and study samples, with good stability of the chromatographic separation (retention time drift within 2-4 s intrabatch and 5 s interbatch) and excellent mass accuracy (average error &lt; 2 ppm). The use of the proposed criteria allowed for the identification of handling errors, instrumental issues, and potential batch effects. This is the first elaboration of harmonized QA/QC criteria applied across multiple laboratories to assess the quality of data generated by nontargeted analysis of human samples.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical chemistry

  • ISSN

    0003-2700

  • e-ISSN

    1520-6882

  • Volume of the periodical

    94

  • Issue of the periodical within the volume

    22

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    11

  • Pages from-to

    7833-7843

  • UT code for WoS article

    000818957300001

  • EID of the result in the Scopus database

    2-s2.0-85131839239