Comparison of mobility shift affinity capillary electrophoresis and capillary electrophoresis frontal analysis for binding constant determination between human serum albumin and small drugs
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F22%3A00129017" target="_blank" >RIV/00216224:14310/22:00129017 - isvavai.cz</a>
Result on the web
<a href="https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elps.202100320" target="_blank" >https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elps.202100320</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.202100320" target="_blank" >10.1002/elps.202100320</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of mobility shift affinity capillary electrophoresis and capillary electrophoresis frontal analysis for binding constant determination between human serum albumin and small drugs
Original language description
In this study, two capillary electrophoresis–based ligand binding assays, namely, mobility shift affinity capillary electrophoresis (ms-ACE) and capillary electrophoresis-frontal analysis (CE-FA), were applied to determine binding parameters of human serum albumin toward small drugs under similar experimental conditions. The substances S-amlodipine (S-AML), lidocaine (LDC), l-tryptophan (l-TRP), carbamazepine (CBZ), ibuprofen (IBU), and R-verapamil (R-VPM) were used as the main binding partners. The scope of this comparative study was to estimate and compare both the assays in terms of their primary measure's precision and the reproducibility of the derived binding parameters. The effective mobility could be measured with pooled CV values between 0.55% and 7.6%. The precision of the r values was found in the range between 1.5% and 10%. Both assays were not universally applicable. The CE-FA assay could successfully be applied to measure the drugs IBU, CBZ, and LDC, and the interaction toward CBZ, S-AML, l-TRP, and R-VPM could be determined using ms-ACE. The average variabilities of the estimated binding constants were 64% and 67% for CE-FA and ms-ACE, respectively.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/GA19-08358S" target="_blank" >GA19-08358S: New approaches for the study of affinity interaction based on capillary electrophoresis</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electrophoresis
ISSN
0173-0835
e-ISSN
1522-2683
Volume of the periodical
43
Issue of the periodical within the volume
16-17
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
1724-1734
UT code for WoS article
000821928600001
EID of the result in the Scopus database
2-s2.0-85133618859