All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Depth profiling of W–Ta based fusion-relevant samples using picosecond laser ablation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F24%3A00135957" target="_blank" >RIV/00216224:14310/24:00135957 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0584854724000740" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0584854724000740</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.sab.2024.106930" target="_blank" >10.1016/j.sab.2024.106930</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Depth profiling of W–Ta based fusion-relevant samples using picosecond laser ablation

  • Original language description

    This study presents a detailed picosecond LIBS analysis of WTa coatings on Molybdenum substrate with varying layer thicknesses for fusion relevant applications. Ps-LIBS is performed on three WTa layers; two without deuterium (∼7 μm thickness) and one with deuterium (∼1 μm thickness). The LIBS measurements are conducted under argon gas flow at 5±0.2 mbar pressure with different laser pulse energies (1 mJ, 3 mJ) and 100 spectra are recorded consecutively at one spot on the sample for different set of gate delay/gate width (200/200 ns, 300/300 ns, 450/450 ns). The obtained LIBS and Glow-Discharge Optical Emission Spectroscopy (GDOES) depth profiles are compared with the confocal microscopic measurements showing good agreement. Additionally, the ablation rate and layer thickness are calculated for different experimental conditions. The Calibration-Free LIBS approach is used for elemental analysis and the results are compared with GDOES results. The capability of ps-LIBS to quantify Ta in WTa alloy is explored for 2 at.% of Ta. However, due to higher ablation rate of laser and thin coating in WTaD sample, the layer is irradiated in few laser pulse and therefore, CF-LIBS analysis is not performed for it.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10305 - Fluids and plasma physics (including surface physics)

Result continuities

  • Project

    <a href="/en/project/LM2018097" target="_blank" >LM2018097: R&D centre for plasma and nanotechnology surface modifications</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Spectrochimica Acta Part B: Atomic Spectroscopy

  • ISSN

    0584-8547

  • e-ISSN

    1873-3565

  • Volume of the periodical

    216

  • Issue of the periodical within the volume

    June 2024

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    9

  • Pages from-to

    1-9

  • UT code for WoS article

    001272010800001

  • EID of the result in the Scopus database

    2-s2.0-85192099715