Analysis of oxylipins in human plasma: Comparison of ultrahigh-performance liquid chromatography and ultrahigh-performance supercritical fluid chromatography coupled to mass spectrometry
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39910585" target="_blank" >RIV/00216275:25310/17:39910585 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.chroma.2017.06.070" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2017.06.070</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2017.06.070" target="_blank" >10.1016/j.chroma.2017.06.070</a>
Alternative languages
Result language
angličtina
Original language name
Analysis of oxylipins in human plasma: Comparison of ultrahigh-performance liquid chromatography and ultrahigh-performance supercritical fluid chromatography coupled to mass spectrometry
Original language description
The potential of ultrahigh-performance liquid chromatography–mass spectrometry (UHPLC/MS) and ultrahigh-performance supercritical fluid chromatography (UHPSFC) coupled to negative-ion electrospray ionization mass spectrometry (ESI–MS) for the analysis of 46 oxylipins and 2 fatty acid standards is compared in terms of their chromatographic resolution with the emphasis on distinguishing isobaric interferences and the method sensitivity. UHPLC provides the baseline separation of 24 isobaric oxylipins within 13 min, while UHPSFC enables the separation of only 20 isobaric oxylipins within 8 min. Moreover, the UHPLC/ESI–MS method provides an average improvement of sensitivity by 3.5-fold. A similar trend is observed in the analysis of human plasma samples, but lower ion suppression effects caused by lysophospholipids (LPL) are observed in case of UHPSFC/ESI–MS due to better separation of LPL. Both methods are fully applicable for the analysis of oxylipins, but UHPLC/ESI–MS method is preferred due to better separation and higher sensitivity, which results in the identification of 31 oxylipins in human plasma based on available standards and additional tentative 20 identifications based on accurate m/z values and the fragmentation behavior known from the literature.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/LL1302" target="_blank" >LL1302: Mass Spectrometry in Cancer Research: Lipid Biomarkers for Early Diagnostics</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Volume of the periodical
1511
Issue of the periodical within the volume
August
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
15
Pages from-to
107-121
UT code for WoS article
000406986000013
EID of the result in the Scopus database
2-s2.0-85022049489