Proposal of technical measures for a partial discharge detection system based on real measurement

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU103991" target="_blank" >RIV/00216305:26220/13:PU103991 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Proposal of technical measures for a partial discharge detection system based on real measurement

  • Original language description

    The article presents results of the measurement of partial discharge (PD) activity in power oil transformers. The method is based on measurement of electromagnetic waves in UHF spectrum produced by PD. The measurement of PD activity has been made on eight power transformers in the Dukovany nuclear power plant in the Czech Republic. The initial experimental measurement, which was under full working arrangements, has been accompanied by some issues. The recorded signals contained strong interference. It has been estimated, that the source of the interference is probably situated in the high voltage bushings, which feed the transformer from a turbo-generator. The interfering signal in form of electromagnetic waves has propagated through the air vicinity and it has coupled to the sensing heads. It has been found that the proper shielding is a crucial factor, while the PD signal level is far below the level of the interference. Further experiments have been conducted with an additional shielding and the interference level significantly decreased. The report on the results of the experimental measurement is given in the paper. There are shown waveform examples of the interfering signal. Further, the design of construction measure of the sensor casing, which allows to improve the shielding, is presented also. The functionality of proposed measure has been demonstrated in laboratory.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/FR-TI1%2F001" target="_blank" >FR-TI1/001: Research and development of discharge activity detection inside of oil transformers</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of PIERS 2013 in Taipei, March 25-28, 2013

  • ISBN

    978-1-934142-24-0

  • ISSN

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    1233-1236

  • Publisher name

    The Electromagnetics Academy

  • Place of publication

    Taipei

  • Event location

    Taipei

  • Event date

    Mar 25, 2013

  • Type of event by nationality

    WRD - Celosvětová akce