Possibilities of Reducing Radiation Dose in Computed Tomography Examinations in Various Age Groups Using an Iterative Model-Based Reconstruction Technique

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F16%3APU122003" target="_blank" >RIV/00216305:26220/16:PU122003 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216224:14110/16:00095995

  • Result on the web

    <a href="https://www.omicsonline.org/open-access/possibilities-of-reducing-radiation-dose-in-computed-tomography-examinations-in-various-age-groups-using-an-iterative-modelbased-r-2161-0665-1000302.php?aid=82592" target="_blank" >https://www.omicsonline.org/open-access/possibilities-of-reducing-radiation-dose-in-computed-tomography-examinations-in-various-age-groups-using-an-iterative-modelbased-r-2161-0665-1000302.php?aid=82592</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.4172/2161-0665.1000302" target="_blank" >10.4172/2161-0665.1000302</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Possibilities of Reducing Radiation Dose in Computed Tomography Examinations in Various Age Groups Using an Iterative Model-Based Reconstruction Technique

  • Original language description

    Aim: To determine whether iterative model-based reconstruction (IMR) technique can preserve computed tomography (CT) image quality when the radiation dose is reduced to 20% of the original value. Methods: CT examination of the neck, mediastinum, or stomach was performed using standard protocols with a Philips Healthcare MDCT 64. Fifty imaging studies were evaluated. The patient’s set was divided into three groups: Young, Preadolescent, and Adult. Four experienced evaluators assessed the CT scans reconstructed using filtered back projection (FBP) and IMR technique (using the L1BR, L2BR, and L2BSP levels) at a 100% dose and at a dose reduced by 80%. The dose was reduced by a decrease in milliampere seconds (mAs). Image noise, artifacts, anatomical details, sharpness, low-contrast resolution, general impression of the reconstructed image, possibility of influencing the description, and possibility of influencing the examination’s conclusion were assessed. FBP at 100% of mAs was always used as the basis for comparison. Decrease in a parameter meant a negative point score while an improvement was marked as positive. Subsequently, objective measurement of image quality was also performed. Results: The greatest improvement in image quality (relative to the quality of images reconstructed using FBP with 100% dose) was achieved using IMR L2BR reconstruction, which can be recommended as optimal. The IMR L2BR reconstruction method was statistically demonstrated to have the best performance among the tested methods in suppressing noise and artifacts. In relation to the selected indications, this method allows a reduction in dose by as much as 80%. The effect of IMR was less marked among the youngest patients than in the remaining two patient groups. Conclusion: The study demonstrated that use of the IMR technique preserves diagnostic indications even with a markedly reduced dose in CT examinations of the neck, thorax, and abdomen in various age groups.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JD - Use of computers, robotics and its application

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Pediatrics & Therapeutics

  • ISSN

    2161-0665

  • e-ISSN

  • Volume of the periodical

    6

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    7

  • Pages from-to

    1-7

  • UT code for WoS article

  • EID of the result in the Scopus database