Conceptual and detail design of SW (TN01000029/4-V1) – 85%UNIS
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00532304%3A_____%2F20%3AN0000005" target="_blank" >RIV/00532304:_____/20:N0000005 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Conceptual and detail design of SW (TN01000029/4-V1) – 85%UNIS
Original language description
SW single-channel programmable control units EHXX for aircraft turbine engines. The application area of application is GE turbine engines of the H series, which are currently controlled by analog ECUs and therefore have a fundamentally limited modifiability according to customer requirements. The EHXX control unit represents a part of the electronic engine control system in the aircraft unit. Its function is to process system inputs and set and control system outputs according to an internal algorithm.
Czech name
—
Czech description
—
Classification
Type
R - Software
CEP classification
—
OECD FORD branch
20205 - Automation and control systems
Result continuities
Project
<a href="/en/project/TN01000029" target="_blank" >TN01000029: National Competence Centre for Aeronautics and Space</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Data specific for result type
Internal product ID
EEC EHXX
Technical parameters
SW architecture - divided into three parts: In Part 1, the processor is initialized. This initialization is performed whenever the power is connected to the processor or the processor is reset. During initialization, registry, pointer, and system settings are made. In Part 2, the interrupt setting is performed after the initialization is completed. Interrupts are set to events triggered by analog digital converters, frequency measurement modules, PWM generation modules for el. engines and timer. In the 3rd part of the architecture, the main SW loop is started. This is where periodic calls to the control logic function and output I / O settings take place. In parallel with the operation of the main loop, the I / O status and power control information is updated for the control logic based on the triggers. engine.
Economical parameters
------
Owner IČO
00532304
Owner name
UNIS, a.s.