Ultrasound-guided versus conventional femoral venipuncture for catheter ablation of atrial fibrillation: a multicentre randomized efficacy and safety trial (ULTRA-FAST trial)
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F27283933%3A_____%2F17%3A00004715" target="_blank" >RIV/27283933:_____/17:00004715 - isvavai.cz</a>
Alternative codes found
RIV/00023001:_____/18:00077074
Result on the web
<a href="http://academic.oup.com/europace/article-pdf/doi/10.1093/europace/eux175/17634664/eux175.pdf" target="_blank" >http://academic.oup.com/europace/article-pdf/doi/10.1093/europace/eux175/17634664/eux175.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/eux175" target="_blank" >10.1093/europace/eux175</a>
Alternative languages
Result language
angličtina
Original language name
Ultrasound-guided versus conventional femoral venipuncture for catheter ablation of atrial fibrillation: a multicentre randomized efficacy and safety trial (ULTRA-FAST trial)
Original language description
Complications of catheter ablation for atrial fibrillation (AF) are frequently related to vascular access. We hypothesized that ultrasound-guided (USG) venipuncture may facilitate the procedure and reduce complication rates. Methods and results: We conducted a multicentre, randomized trial in patients undergoing catheter ablation for AF on uninterrupted anticoagulation therapy. The study enrolled consecutive 320 patients (age: 63 ± 8 years; male: 62%) and were randomized to USG or conventional venipuncture in 1:1 fashion. It was prematurely terminated due to substantially lower-than-expected complication rates, which doubled the population size needed to maintain statistical power. While the complication rates did not differ between two study arms (0.6% vs. 1.9%, P = 0.62), intra-procedural outcome measures were in favour of the USG approach (puncture time, 288 vs. 369 s, P < 0.001; first pass success, 74% vs. 20%, P < 0.001; extra puncture attempts 0.5 vs. 2.1, P < 0.001; inadvertent arterial puncture 0.07 vs. 0.25, P < 0.001; unsuccessful cannulation 0.6% vs. 14%, P < 0.001). Though these measures varied between trainees (49% of procedures) and expert operators, between-arm differences (except for unsuccessful cannulation) were comparably significant in favour of USG approach for both subgroups. Conclusions: Ultrasound-guided puncture of femoral veins was associated with preferable intra-procedural outcomes, though the major complication rates were not reduced. Both trainees and expert operators benefited from the USG strategy.
Czech name
—
Czech description
—
Classification
Type
J<sub>ost</sub> - Miscellaneous article in a specialist periodical
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
EP Europace
ISSN
1099-5129
e-ISSN
—
Volume of the periodical
—
Issue of the periodical within the volume
May
Country of publishing house
GB - UNITED KINGDOM
Number of pages
2
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—