All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Piezoelectric biosensor for the determination of Tumor Necrosis Factor Alpha

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F18%3A43889330" target="_blank" >RIV/60162694:G44__/18:43889330 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S0039914017310731" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914017310731</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2017.10.031" target="_blank" >10.1016/j.talanta.2017.10.031</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Piezoelectric biosensor for the determination of Tumor Necrosis Factor Alpha

  • Original language description

    Tumor Necrosis Factor Alpha (TNF alpha) is an important marker of inflammatory processes in human body. In the current healthcare, determination of TNFa blood or plasma level is done by Enzyme Linked Immuno-Sorbent Assay (ELISA) as a primary choice method. Piezoelectric immunosensors are analytical platform recording affinity interactions on their surface. It is inferred that the immunosensors would be a functional alternative to the ELISA. In this study, antibody against TNF alpha was immobilized on Quartz Crystal Microbalance (QCM) sensor and the same was made on magnetic particles. Human TNFa was measured in a way of interaction with QCM surface and then the particles were applied. The assay exerted sufficient limit of detection equal to 1.62 pg/ml and it also fully correlated with standard ELISA tests. No interference by interleukin 6 or albumin was observed. Long term stability of the immunosensors lasting for at least three months was found. The immunosensors appears to be readily for practical performance and it would be an alternative to the standard ELISA especially when diagnoses made in field, homecare conditions or conditions of small hospitals as an emergency test.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

  • Volume of the periodical

    178

  • Issue of the periodical within the volume

    February

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    4

  • Pages from-to

    970-973

  • UT code for WoS article

    000416615500129

  • EID of the result in the Scopus database

    2-s2.0-85032383725