Current approaches to the derivatization of Chemical Weapons Convention-related alcohols for on-site gas chromatographic analysis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG45__%2F24%3A00560481" target="_blank" >RIV/60162694:G45__/24:00560481 - isvavai.cz</a>
Result on the web
<a href="https://www.mdpi.com/2504-3900/92/1/13" target="_blank" >https://www.mdpi.com/2504-3900/92/1/13</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/proceedings2023092013" target="_blank" >10.3390/proceedings2023092013</a>
Alternative languages
Result language
angličtina
Original language name
Current approaches to the derivatization of Chemical Weapons Convention-related alcohols for on-site gas chromatographic analysis
Original language description
The task of deployable military laboratories is to perform the fast identification of chemical warfare agents (CWAs) and related chemicals in various types of samples in field conditions. Identification is limited by the time and equipment of mobile laboratories. Polar degradation products are commonly derivatized by a procedure using N,O-Bis(trimethylsilyl)trifluoroacetamide (BSTFA) [1,2], which is time-consuming, and the resulting chromatograms often contain a number of artifacts that hinder their identification [3]. This work describes the development and optimization of an alternative trimethylsilylation (TMS) procedure for on-site identification. The goal was to develop a fast and robust method that was efficient without heating, producing clean chromatograms. The analytes were precursors and degradation products of blistering (thiodiglycol, ethyldiethanolamine, methyldiethanolamine, triethanolamine), nerve (N,N-diisopropylamino ethanol), and psychoactive (3-quinuclidinol) CWAs. Ten TMS reagents were compared in terms of their derivatization efficiency. The solvent effect, catalyst addition effect, and the time and temperature of derivatization were studied and optimized. The stability of the derivatives was observed over time, and chromatogram artifacts were monitored. The original recommended and widely used method of derivatizing alcohol for 30 min at 60 °C in acetonitrile using BSTFA was overcome using three optimized procedures with different TMS reagents. They achieved high and stable yields in an acetone environment already at room temperature and a reaction lasting 5 min. Due to the same chemical structure of the resulting compounds (TMS-derivatives), it was possible to use established mass spectral databases. Optimized procedures were applied to environmental (water, sand) and urban (acrylic paint, asphalt-aluminum paint, concrete) samples contaminated with the studied alcohol. The results obtained on a benchtop gas chromatograph were validated afterward on a field device used by the deployable chemical laboratory of the Czech Army following their standard operating procedures for sample preparation. The developed methods are useful for military teams and stationary analytical laboratories whose task is the unambiguous identification of CWAs and related compounds in various samples.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
10500 - Earth and related environmental sciences
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings
ISBN
—
ISSN
2504-3900
e-ISSN
2504-3900
Number of pages
2
Pages from-to
13-14
Publisher name
MDPI
Place of publication
Tallinn, Estonsko
Event location
Tallinn, Estonsko
Event date
Oct 9, 2023
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—