Enzyme linked immunosorbent assay in analysis of deoxynivalenol: Investigation of impact of sample matrix on results accuracy
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F14%3A43898065" target="_blank" >RIV/60461373:22330/14:43898065 - isvavai.cz</a>
Result on the web
<a href="http://download.springer.com/static/pdf/636/art%253A10.1007%252Fs00216-013-7463-3.pdf?auth66=1423854967_9b6a3b3cc61e44e01f576199fa388794&ext=.pdf" target="_blank" >http://download.springer.com/static/pdf/636/art%253A10.1007%252Fs00216-013-7463-3.pdf?auth66=1423854967_9b6a3b3cc61e44e01f576199fa388794&ext=.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-013-7463-3" target="_blank" >10.1007/s00216-013-7463-3</a>
Alternative languages
Result language
angličtina
Original language name
Enzyme linked immunosorbent assay in analysis of deoxynivalenol: Investigation of impact of sample matrix on results accuracy
Original language description
Enzyme-linked immunosorbent assay (ELISA) represents a bioanalytical strategy frequently used for rapid screening of mycotoxin deoxynivalenol (DON) in cereals and derived products. Due to a considerable affinity of some anti-DON antibodies to structurally similar DON metabolites, such as DON-3-glucoside (DON-3-Glc) and 3-acetyl-DON (3-ADON), a significant overestimation of DON concentrations may occur. A validation study of six commercial DON-dedicated ELISA kits, namely Ridascreen DON, Ridascreen FASTDON, DON EIA, AgraQuant DON Assay, Veratox 5/5 and Veratox HS was carried out on wheat, barley and malt matrices. Performance characteristics of all tested ELISAs were determined using aqueous solutions of DON, DON-3-Glc and 3-ADON analytical standards,further with extracts of artificially spiked blank cereals and finally with matrix-matched standards of all three compounds. In the final phase, the accuracy of data was assessed through a comparison of DON concentrations determined by pa
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Volume of the periodical
406
Issue of the periodical within the volume
2
Country of publishing house
DE - GERMANY
Number of pages
10
Pages from-to
505-514
UT code for WoS article
000329626600014
EID of the result in the Scopus database
—