All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Poly(HEMA) brushes emerging as a new platform for direct detection of food pathogen in milk samples

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F11%3A00362960" target="_blank" >RIV/61389013:_____/11:00362960 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11110/11:10304

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.bios.2011.05.021" target="_blank" >http://dx.doi.org/10.1016/j.bios.2011.05.021</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.bios.2011.05.021" target="_blank" >10.1016/j.bios.2011.05.021</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Poly(HEMA) brushes emerging as a new platform for direct detection of food pathogen in milk samples

  • Original language description

    The attachment of antibodies onto poly(HEMA) brushes prepared by surface initiated ATRP provided a successful way to fabricate SPR biosensors capable of in-real time detection Cronobacter at concentrations down to 106 cells mL1 in milk. Non-specific responses to deposition of non-targeted compounds ruled out other biosensors based on poly(MeOEGMA) and poly(HOEGMA) brushes or SAMs of EG2/COEG and EG6 from detection of Cronobacter at low concentrations even if the lowest detection limit of 104 cells mL1 in PBS was reached by biosensor based on SAM of EG6. Owing to well-controlled character of ATRP it was possible to minimize the thickness of the polymer brushes films so that the fouling could be still suppressed while the capture of antigens by antibodies immobilized on the brush layer could take place close to the gold SPR surface to provide a stronger optical response.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Biosensors and Bioeletronics

  • ISSN

    0956-5663

  • e-ISSN

  • Volume of the periodical

    26

  • Issue of the periodical within the volume

    11

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    4545-4551

  • UT code for WoS article

    000293104100046

  • EID of the result in the Scopus database